Installation
3A3956D
17
4.
Relieve pressure between the remote filling station
pump (P) and the Auto-Fill Shut Off (S):
a.
Open ball valve (bv) (F
released and excess fluid will drain out of the
drain tube (dt) and into the lubrication collection
container (N).
b.
Close ball valve (bv) when all pressure has
been relieved.
NOTE:
The pin may not drop and the Auto-Fill
Shut Off may not reset because the tank is full.
However, when the pump begins using the
grease, the pin resets. The pin must reset
before the next cycle of refilling.
5.
Disconnect lubrication supply hose from Auto-Fill
(S).
6.
Install plugs in the Auto-Fill Shut Off inlet and the
refilling line (V) to prevent contaminants from enter-
ing the pump.
F
IG
. 16: In line installation shown
bv
G
dt
H
F
IG
. 17
pin
drops