background image

Instructions 

4

332519J

8. Install vent valve (1) to pump surface using the 3 

cap screws (4) included in the kit (F

IG

. 5). Hold the 

vent valve tight to the surface of the pump to ensure 

o-rings stay in place during installation.Torque 

screws to 17-19 ft-lbs (23-26 N.m).

9. Install lubrication line to vent valve pump outlet port 

marked “0” (F

IG

. 6).

10. In the inlet port marked “1” (F

IG

. 6) install either:

a plug (10). 

inlet plumbing necessary to attach a fill pump. 

NOTE:

 

For tube-in-tube pump models, the “1” inlet can 

be used as a fill port.

For models equipped with a follower plate, with

-

out a tube-in-tube, the “1” inlet deposits grease 

on top of the follower plate.

11. Connect cable (d) to valve cartridge (c) (F

IG

. 7).

12. Install other end of cable (d) to solenoid control 

device.

NOTE:

 

Cable (d) is available from Graco. See Accesso

-

ries, page 5 for a list of available cables. 

Connector termination is a Deutsch DT-04-2P.

Solenoid inputs are not polarity dependent. Volt

-

age can be applied in either direction.

Solenoid should be activated when the pump is 

running. See wiring diagrams in pump manual 

for more details.

13. Reconnect pump to main power supply.

14. Test system to ensure proper operation.

F

IG

. 5

F

IG

. 6

4

1

10

F

IG

. 7

d

c

Reviews: