background image

Parts

332519J

5

Parts

Accessories

Technical Data

.

*

Dyna-Star HP Pump Models are rated for 5000 psi (34.47 MPa, 344 bar) maximum working pressure, however, when a vent valve is installed on 

the HP Pump, the maximum working pressure must be reduced to 3500 psi (24.1 MPa, 241 bar).

**Flow capability depends on viscosity, type of fluid, temperature, etc. 

California Proposition 65

Ref  Description

Qty

1

MANIFOLD, electric vent valve

1

2

VALVE, cartridge, 24VDC

1

3

VALVE, pressure relief, 3500 psi

1

4

SCREW, cap, socket, M8 x 1.25

3

8

O-RING

2

9

PLUG, pipe, 1/8 in. npt

1

10 PLUG, 1/4 in. npt

1

Part No. Description

24N402 CABLE, 6 ft, vent valve, 2 pin for vent valve 

control

77X546 CABLE, power extension, 15 ft (4.6m), Injec

-

tor System

1

2

8

4

3

9

10

Vent Valve for Dyna-Star HP

US

Metric

Maximum working pressure*

3500 psi

24.1 MPa, 241 bar

Inlet/Outlet Sizes

Outlet (marked “0”)

3/8 in. npt(f)

Inlet (refill - marked “1”)

3/8 in. npt(f)

Pressure Relief Valve

Factory Set Pressure

4000 psi + 250 psi

27 MPa, 275 bar + 10%

Reset Pressure

80% of set pressure

Relief Rate**

0.1 gallons/minute @3500 psi 

0.4 liters/minute @24.1 MPa. 241 bar

Solenoid Valve 

Flow**

Up to gpm 0.2 gallons/minute, 
40 in

3

/minute

0.65 liters/minute

Wetted materials

Zinc plated steel, carbon steel, aluminum, fluoroelastomer, polyurethane

Weight

4.0 lbs

1.8 kg

IP Rating

IP69K

Solenoid Coil

Resistance (DC) (Ohms) @ 68°F (20°C) Initial Current Draw (Amps)

24 VDC

28.8

0.83

CALIFORNIA RESIDENTS

 WARNING:

 Cancer and reproductive harm – www.P65warnings.ca.gov.

Reviews: