Electric Motor Starter
16
3A2247A
5.
Remove motor junction box cover (J).
6.
Tilt motor junction box cover back and disconnect
three power leads (brown, black, and grey wires)
and the yellow and green ground wire (see
Wiring
Diagram
, page 29).
7.
Remove cable strain relief fitting (S) from motor
junction cover and pull motor power leads and motor
ground wire from motor junction cover.
8.
Remove six screws (200) from motor mounting
bracket (195).
9.
Remove motor starter assembly (198).
Installation
3 Phase, 400 VAC, 50 Hz, Electric Motor Starter
1.
Install motor starter (198) on motor starter bracket
(195).
2.
Install six screws (200), into motor starter (198).
Torque screws to 20 in-lb (2.3 N•m).
3.
Remove motor junction box cover (J).
4.
Remove strain relief fitting (S) from motor junction
box cover (J).
5.
Slide strain relief fitting (S) over motor cable power
leads.
6.
Screw strain relief fitting (S) into motor junction box
cover (J).
ti18700a
S
J
204
205
43
30
119
175
30
190
192
191
193
ti18617a
200
198
195
ti18700a
S
J