Technical Data
32
311828F
Key
A
0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure or 7.5 MPa, 75 bar (1050 psi) hydraulic oil pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure or 4.2 MPa, 42 bar (600 psi) hydraulic oil pressure
Test Fluid: No. 10 Weight Oil
Dura-Flo 1200 Pumps with Premier Air Motors, Pump Ratio 67:1
Fluid Flow in gpm (lpm)
1.0
(3.8)
2.0
(7.6)
3.0
(11.4)
4.0
(15.2)
5.0
(19.0)
Fl
uid
Pressu
re
A
B
psi (MPa, bar)
3500 (24.1, 241)
3000 (21.0, 210)
2500 (17.2, 172)
2000 (14.0, 140)
1500 (10.3, 103)
1000 (7.0, 70)
500 (3.5, 35)
0
C
A
B
C
Air Flo
w
(s
cfm)
50
100
150
200
250
4000 (28.0, 280)
4500 (31.5, 315)
5000 (35.0, 350)
12.5
25
37.5
50
62.5
Cycles per Minute
Dura-Flo 1200 Pumps with NXT Model 6500 Air Motors, Pump Ratio 45:1
Fluid Flow in gpm (lpm)
1.0
(3.8)
2.0
(7.6)
3.0
(11.4)
4.0
(15.2)
5.0
(19.0)
Fl
ui
d
Pre
ssu
re
A
B
psi (MPa, bar)
3500 (24.1, 241)
3000 (21.0, 210)
2500 (17.2, 172)
2000 (14.0, 140)
1500 (10.3, 103)
1000 (7.0, 70)
500 (3.5, 35)
0
C
A
B
C
Air Flo
w
(scfm)
50
100
150
200
250
4000 (28.0, 280)
4500 (31.5, 315)
5000 (35.0, 350)
12.5
25
37.5
50
62.5
Cycles per Minute
Summary of Contents for Dura-Flo 7847
Page 19: ...Repair 311828F 19...