Troubleshooting
26
3A4442B
Pump is difficult to prime
Air in pump or hose
Check and tighten all fluid
connections. Cycle pump as slowly
as possible during priming.
Intake valve or piston valve is stuck
or leaking
Clean intake and piston valve. Be
sure ball seat is not nicked or worn
and that ball seats well.
Reassemble valve.
Pump packings are worn
Replace pump packings; see pump
manual.
Material is too thick
Thin the material according to
supplier recommendations.
Hopper connections are not tight or
elbow o-ring is damaged or missing
Check hopper connections and
tighten as necessary. Inspect for
o-ring. Replace o-ring if it is
damaged.
No display, sprayer operates
Display is damaged or has bad
connection
Check connections. Replace
display.
VIBRA-FLO shaker does not run
No power
Make certain sprayer and shaker
ON/OFF switches are
ON
.
Shaker coil is defective
Replace shaker coil.
VIBRA-FLO shaker is too loud
Adjust shaker speed.
Turn shaker adjustment knob to a
lower setting.
Coil contacting armature block
Use feeler gauge to adjust shaker
gap. See
VIBRA-FLO Shaker
Adjustment
, page 15.
Problem
Cause
Solution