Operation
309455C
13
Low Voltage Adjustment (For Pro Xp Smart Guns Only)
NOTE:
See the Pro Xp instruction manual for complete
information on navigating and using the Smart module
display screens.
The low voltage setting is user adjustable. To access
the low voltage setting screen when in operating Mode,
press the LO SET button (LS) momentarily. The screen
will display the current low voltage setting (LV). The pos-
sible ranges are:
•
85 kV guns: 40-85 kV
•
60 kV guns: 30-60 kV
Set the Voltage Adjustment switch (VA) to LO. Press the
LO SET button repeatedly to increase the setting in
increments of 5. When the display reaches the maxi-
mum setting it will return to the minimum setting for your
gun. Continue pressing the button until you reach the
desired setting.
NOTE:
After 2 seconds of inactivity the display will
return to the Operating Screen.
NOTE:
The low voltage setting may be locked. When
locked, an image (LK) appears on the screen. See your
Pro Xp instruction manual for further information.
Fig. 9. Low Voltage Setting Screen, in Locked State
(Pro Xp Guns)
LK
LO
VA
LV
LS
TI19337A
Summary of Contents for 309455C
Page 11: ...Operation 309455C 11 ...