background image

Graco 5-Year Meter and Valve Warranty

3A6673B

43

Graco 5-Year Meter and Valve Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be 
free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of 
any special, extended, or limited warranty published by Graco, Graco will, for a period from the date of sale as defined in 
the table below, repair or replace equipment covered by this warranty and determined by Graco to be defective. This 
warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or 
wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, 
accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or 
wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not 
supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, 
accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco 
distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge 
any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the 
equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which 
charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A 
PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees 
that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury 
to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty 
must be brought within one (1) year past the warranty period, or two (2) years for all other parts.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR 
COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco 

(such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide 
purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying 
equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to 
a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal 
proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in 
English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous 
documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou 
indirectement, avec les procédures concernées.

Graco Information 

For the latest information about Graco products, visit 

www.graco.com

.

For patent information, see 

www.graco.com/patents

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655,   Fax: 612-378-3590

Graco 5-Year Meter and Valve Extended Warranty

Components

Warranty Period

Structural Components

5 years

Electronics

3 years

Wear Parts - including but not limited to o-rings, seals and valves

1 year

Summary of Contents for 26C354

Page 1: ...s For professional use only See page 6 for model information 1500 psi 10 MPa 103 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and relate...

Page 2: ...tallation 10 Pressure Relief Procedure 10 Grounding 10 Pre Installation Procedure 10 Flushing 11 Install the Metered Dispense Valve 11 Install the Extension Tube 12 Install the Nozzle 12 Preset Mode 1...

Page 3: ...libration 29 Manual Calibration 30 DISPENSE 31 Screen Identification 31 UTILITY MENU 33 Service 35 Battery Replacement 35 Parts 36 Parts 37 Related Kits 37 Troubleshooting 38 Error Codes 40 Technical...

Page 4: ...diately EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or...

Page 5: ...not plug or unplug power cords or turn lights on or off when flammable fumes are present Use only grounded hoses Stop operation immediately if static sparking occurs or you feel a shock Do not use equ...

Page 6: ...Antifreeze Antifreeze 8 30 26C364 1 2 BSPP Flexible Automatic Oil 8 30 26C365 1 2 BSPP Flexible Antifreeze Antifreeze 8 30 26C368 1 2 BSPP Rigid High Flow Oil 18 68 26C369 1 2 BSPP Flexible High Flow...

Page 7: ...gation ARROWS UP DOWN LEFT RIGHT and a center ENTER button Arrows Move the cursor on the display ENTER button Used to select or store an entry Locking and Unlocking the Trigger The locking trigger fea...

Page 8: ...Overview 8 3A6673B Opening and Closing the Nozzle To open the nozzle rotate the nozzle clockwise To close the nozzle rotate the nozzle counter clockwise FIG 3 Open Closed...

Page 9: ...g the metered dispense valve on a console Oil Bar An Oil Bar Kit is available for mounting one to three metered dispense valves Contact your Graco Distributor for ordering details NOTE The Utility Men...

Page 10: ...ation Procedure 1 See Relieve pressure page 10 2 Close fluid shut off valve B FIG 4 page 9 3 Ground the hose and reel or console see Grounding page 10 4 Flush equipment See Flushing page 11 This equip...

Page 11: ...the container to avoid it becoming loose during flushing c For multiple dispensepositions first flush the dispense position farthest from the pump then work toward the pump 4 Slowly open the fluid shu...

Page 12: ...e wrench on the flats of the nozzle bushing tighten firmly FIG 10 3 Opentheautomatictwistlocknozzleand all fluid shut off valves Start pump to pressurize system 4 Toensuredispensingaccuracy purgeall a...

Page 13: ...valve should be calibrated prior to using it for the first time Calibrating the metered dispense valve assures that the dispenses are accurate Calibration factors can vary due to fluid viscosity and...

Page 14: ...se valve calibration FIG 15 NOTE The on this screen is used for Manual Calibration See Manual Calibration instructions on page 15 6 Dispense exactly one quart or one liter of fluid into the one quart...

Page 15: ...d to set that number 1 Follow steps 1 4 of the Calibration instructions beginning on page 13 2 Use the RIGHT ARROW button on the keypad to highlight and press the center ENTER button on the keypad to...

Page 16: ...sized clean calibrated volumetric flask Note this volume as the VOLUME DISPENSED see Calculating k factor Step 11 page 18 2 Record the volume displayed on the metered dispense valve Note this volume a...

Page 17: ...the RIGHT ARROW button on the keypad to highlight and press the center ENTER button on the keypad to select the option FIG 27 8 The k factor adjustment screen shown in FIG 28 displays 9 Use the UP and...

Page 18: ...ENSE A BANNER Unique identification name See Utility Menu Set Up BANNER page 23 for instructions for creating the banner B BATTERY INDICATOR When the batter ies are fully charged the battery is com pl...

Page 19: ...mount of fluid previ ously dispensed K INCREASE DECREASE ARROW The up down arrow on the screen indicates the user can increase or decrease the PRESET quantity before starting the dispense Use the UP o...

Page 20: ...If RESET was selected the field will show 0 000 STOP Function During the dispense the word STOP FIG 32 is highlighted on the lower left corner of the dispense screen To interrupt the dispense at any...

Page 21: ...e unit of measurement displayed is determined by the Unit of Measurement criteria selected in UTILITY MENU SET UP UNIT OF MEA SURE page 23 GO BACK Returns to Main Menu screen RESET Resets the Resettab...

Page 22: ...ays the meter is ready to use SET UP SCREENS The SET UP Menu includes the following options UNIT OF MEASURE BANNER CALIBRATE and A second SET UP screen is accessed by selecting the This screen include...

Page 23: ...assign a name to the meter such as Meter 1 Meter 2 etc This is useful in shops that have more than one meter in their system Names can be made up of anycombination of letters or numbers The maximum nu...

Page 24: ...uage screen it can be configured to display in ENGLISH FRENCH GERMAN ITALIAN A second language screen is accessed by selecting the This screen includes language options of POLISH PORTUGUESE RUSSIAN AN...

Page 25: ...option is being set up The example in FIG 46 shows PRESET1 This means you are setting up the PRESET parameters for PRE SET1 in the list R NAME Additional information about the PRESET such as the type...

Page 26: ...to PRESET Menu Screen FLIP DISPLAY Allows for viewing data on the metered dispensevalvedisplayupsidedownforoilbar installation After selecting FLIP DISPLAY the meter display goes blank for about 10 s...

Page 27: ...button after RESET is selected Continue to step 4 4 Press and hold the LEFT ARROW button 5 While still holding down the LEFT ARROW button press the CENTER button DEVICE INFORMATION See page 21 for a...

Page 28: ...ds When a tag or voucher is referenced in this manual it refers to a card programmed to perform the designated function Enable Pulse FC Mode 1 Press the center ENTER button on the keypad to activate t...

Page 29: ...first time Calibrating the metered dispense valve assures that dispenses are accurate Calibration factors can vary due to fluid viscosity and flow rate Calibrate the metered dispense valve for specif...

Page 30: ...ER button on the keypad to select END A screen displaying the quantity of fluid dispensed displays FIG 61 shows an example of the dispensed volume screen 7 Press the center ENTER button on the keypad...

Page 31: ...r ENTER button on the keypad to select ENTER and save the new calibration factor AfterselectingENTERtheMainMenu screen shown in FIG 66 displays DISPENSE Screen Identification A BANNER Name of the flui...

Page 32: ...the total amount of fluid that can be dispensed Adjustments cannot be made to these parameters 3 Squeeze the trigger to begin dispensing fluid A numeric volume of dispensed fluid displays in field D...

Page 33: ...reen shown in FIG 69 displays 3 If UTILITY MENU is not highlighted use the DOWN ARROW on the key pad to highlight it 4 Press the center ENTER button on the key pad to select UTILITY MENU 5 The UTILITY...

Page 34: ...ilbar installation After selecting FLIP DISPLAY the meter display goes blank for about 10 seconds After approximately 10 seconds the screens shown in FIG 72 FIG 73 display When the MAIN MENU Screen sh...

Page 35: ...To change the battery 1 Remove screws 36 from the battery compartment cover 5 2 Use a small flatscrewdriver to gently pry the cover away from the metered dispense valve housing on the bottom side of...

Page 36: ...Parts 36 3A6673B Parts FIG 78 19 37 29 28 27 5 36 2 3 14 17 21 20 15 18 6 16 10 4 13 12...

Page 37: ...0 3 4 14 BSPP 10 155332 PACKING o ring 1 12 HOUSING metered dispense valve 1 13 131258 PACKING square ring 1 14 25D904 VALVE metered dispense valve assy 1 15 25M601 1 16 129830 COVER trigger guard 1 1...

Page 38: ...If the problem remains contact your Graco distributor for repair or replacement Pump pressure is low Increase pump pressure Twist lock nozzle not fully open Aim nozzle into bucket or rag Fully open no...

Page 39: ...e connection Apply PTFE tape leave a minimum of two engaged threads uncovered for electrical continuity or sealant to threads of hose and tighten the connection Poor swivel metered dispense valve hous...

Page 40: ...al gear Ensure that your flow rate is not higher than 18 gpm 68 lpm For further assistance contact your Graco distributor Reed switch malfunction Replace electronic bezel housing Unit was dropped or u...

Page 41: ...maximum recorded dispensed volume 9999 units maximum preset volume 9999 units Inlet 1 2 14 npt or 3 4 14 npt Outlet 3 4 16 straight thread o ring boss Operating temperature range 4 F to 158 F 16 C to...

Page 42: ...including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e au...

Page 43: ...le obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for...

Page 44: ...hanges at any time without notice Original instructions This manual contains English MM 3A6673 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Reviews: