Preset Mode
18
3A6673B
11. Calculate the new k-factor using the
following equation:
Example:
Kcurrent = 169
Volume displayed on metered dispense valve
= 0.970 quart
Volume dispensed = 1 quart
Round to the nearest whole number: 163.9 =
164.
NOTE:
The unit of measurement for both
volumes must be the same in the above
equation.
12. Use the UP or DOWN ARROWS to
adjust the k-factor to the k-factor (Knew)
calculated in Step 11.
See Table 1, page 18 for recommended fluid
calibration factors.
NOTE:
The calibration number may vary
slightly due to temperature or rate of flow.
Table 1
13. Press the center ENTER button on the
keypad to complete the calibration
operation and save the new calibration
factor.
DISPENSE
A
BANNER -
Unique identification name. See
Utility Menu/Set-Up/BANNER, page 23 for
instructions for creating the banner.
B
BATTERY INDICATOR -
When the batter-
ies are fully charged, the battery is com-
pletely filled in. As the battery discharges,
the amount of battery that is filled-in
declines.
C
FUNCTION COMMAND -
Function com-
mand options appear at the bottom of the
display when applicable to the task being
performed. Options when in the Dispense
mode include:
ACTIVATE -
Activates the trigger to begin a
dispense.
PRESET -
Preset dispense adjustment
screen displays.
RESET -
Resets the dispense settings.
ENTER -
Saves changes or updates.
NOTE:
Additional function commands will
appear throughout the following instruc-
tions. when applicable
Fluid
Calibration
Factor
Oil (10W30)
173
Gear Lube
173
ATF
173
Antifreeze
150