Installation 

4

3A4497A

Install the Cable

1. Loosen the captive screws and remove the front 

cover from the enclosure.

2. The cable (23) has bare wires at both ends. Thread 

the shortest end (4 in. [102 mm]) into the enclosure 
through the strain relief bushing (7). See F

IG

. 2. 

3. Connect the cable wires to the left side of the termi-

nal strip (12), as indicated by the label (37). See 
F

IG

. 2 and Table 1.

4. Connect the other end of the cable (5 in. [127 mm]) 

to the appropriate terminal blocks of the EFCM in 
the PD2K Dual Panel Control Enclosure. See F

IG

. 3 

and Table 2.

F

IG

. 2. Connect Cable to Terminal Strip

37

12

TI14279a

7

Table 1: Terminal Strip Wire Connections

Pin No.

Cable Wire Colors

Pin No.

Switch Wires

1

Black

1

Air Flow Switch 1 +

2

White

2

Air Flow Switch 1 -

3

Red

3

Air Flow Switch 2 +

4

Green

4

Air Flow Switch 2 -

5

Orange

5

Pressure Switch 1 +

6

Blue

6

Pressure Switch 1 -

7

White/Black

7

Pressure Switch 2 +

8

Red/Black

8

Pressure Switch 2 -

9

Green/Black

9

Solenoid 1, + (12V), Red

10

Orange/Black

10

Solenoid 1, - (COM), Black

11

Blue/Black

11

Solenoid 2, + (12V), Red

12

Red/White

12

Solenoid 2, - (COM), Black

Summary of Contents for 26A231

Page 1: ...ual Panel Electronic Proportioner For professional use only 26A231 Air Control Module 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure Important Safety Instructions Read all warnings and instructions...

Page 2: ...the identification label Order Gun Flush Box Kit s 15V826 separately see the Gun Flush Box Kit manual Each 15V826 Kit includes one gun flush box and related parts The pressure switch included in Gun...

Page 3: ...weight of the equip ment fluid hoses and stress caused during opera tion Using the equipment as a template mark the mounting holes on the wall at a convenient height for the operator and so equipment...

Page 4: ...o the appropriate terminal blocks of the EFCM in the PD2K Dual Panel Control Enclosure See FIG 3 and Table 2 FIG 2 Connect Cable to Terminal Strip 37 12 TI14279a 7 Table 1 Terminal Strip Wire Connecti...

Page 5: ...s 5 7 6 7 5 Table 2 EFCM Terminal Connections Pin No Cable Wire Colors Pin No EFCM Connector 1 Black 1 6 2 White 2 6 3 Red 3 6 4 Green 4 6 5 Orange 9 7 6 Blue 10 7 7 White Black 11 7 8 Red Black 12 7...

Page 6: ...the switch es in the left side of the enclosure See FIG 4 2 Connect the wires from PS 1 to the right side of the terminal strip 12 pins 5 6 as indicated by the label 38 See FIG 5 and Table 1 3 If usi...

Page 7: ...izing air safety shutoff valve IN port See the gun flush box manual for details on the safety shutoff valve Connect Air Supply to Module Connect a 1 4 in 6 mm OD tube between a clean dry air supply fi...

Page 8: ...NAL rail mount 12 13 115671 CONNECTOR tube 1 4 in OD 1 14 C06061 MUFFLER sintered 1 8 diam 1 15 111328 CONNECTOR tube 5 32 in OD 2 16 SCREW machine truss hd 2 17 104640 GASKET 2 18 103832 SCREW machin...

Page 9: ...Dimensions 3A4497A 9 Dimensions TI14276a TI14278a 6 75 in 171 5 mm 7 50 in 190 5 mm 6 28 in 159 5 mm 4 00 in 101 6 mm 4 00 in 101 6 mm Mounting Holes...

Page 10: ...Dimensions 10 3A4497A...

Page 11: ...231 Air Control Module US Metric Maximum air inlet pressure 100 psi 0 7 MPa 7 bar Inlet Outlet Sizes Air inlet size 1 4 in 6 mm OD tube connector Air exhaust port size 5 32 4mm OD tube connector Weigh...

Page 12: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...