background image

Related Manuals 

2

3A4497A

Contents

Related Manuals   . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Pressure Relief Procedure  . . . . . . . . . . . . . . . . .  3
Location   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mount the Enclosure  . . . . . . . . . . . . . . . . . . . . . . 3
Install the Cable   . . . . . . . . . . . . . . . . . . . . . . . . . 4
Install the Pressure Switch  . . . . . . . . . . . . . . . . .  6
Connect the Gun Flush Box  . . . . . . . . . . . . . . . .  7
Connect Air Supply to Module   . . . . . . . . . . . . . .  7
Replace the Cover   . . . . . . . . . . . . . . . . . . . . . . .  7
Ground the Enclosure  . . . . . . . . . . . . . . . . . . . . . 7

Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Technical Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Graco Standard Warranty  . . . . . . . . . . . . . . . . . . .  12
Graco Information  . . . . . . . . . . . . . . . . . . . . . . . . .  12

Related Manuals

See the following manuals for additional information on 
the ProMix PD2K Proportioner and Gun Flush Box Kits.

Overview

Air Control Module 26A231 provides electrical and air 
connections to enable a ProMix PD2k Dual Panel pro-
portioner to operate two manual spray devices, as well 
as, one or two gun flush boxes, or one or two air shutoff 
valves. See F

IG

. 1 for the identification label.

Order Gun Flush Box Kit(s) 15V826 separately (see the 
Gun Flush Box Kit manual). Each 15V826 Kit includes 
one gun flush box and related parts. The pressure 
switch included in Gun Flush Box Kit 15V826 will be 
installed in this interface module.

Order Air Shutoff Kit(s) 15V823 separately (see the Gun 
Air Shutoff Kit manual). Each 15V823 kit includes one 
air cutoff valve and related parts.

Manual

Description

3A4186

ProMix PD2K Dual Panel Proportioner 
Operation Manual, Manual Systems

332457

ProMix PD2K Proportioner Installation 
Manual, Manual Systems

3A2800

ProMix PD2K Proportioner Repair-Parts 
Manual, Manual Systems

312784

Gun Flush Box Kit Instruction-Parts 
Manual

310745

Gun Air Shutoff Kit Instruction-Parts 
Manual

F

IG

. 1. Air Control Module Identification Label

Artwork No. 294573 Rev. B

GRACO INC.
P.O. Box 1441
Minneapolis, MN 
55440 U.S.A.

.7

7

MAX AIR WPR

MPa

bar

PSI

ProMix

®

 PD2K   AIR CONTROL MODULE

100

PART NO.

SERIES

SERIAL MFG. YR.

Summary of Contents for 26A231

Page 1: ...ual Panel Electronic Proportioner For professional use only 26A231 Air Control Module 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure Important Safety Instructions Read all warnings and instructions...

Page 2: ...the identification label Order Gun Flush Box Kit s 15V826 separately see the Gun Flush Box Kit manual Each 15V826 Kit includes one gun flush box and related parts The pressure switch included in Gun...

Page 3: ...weight of the equip ment fluid hoses and stress caused during opera tion Using the equipment as a template mark the mounting holes on the wall at a convenient height for the operator and so equipment...

Page 4: ...o the appropriate terminal blocks of the EFCM in the PD2K Dual Panel Control Enclosure See FIG 3 and Table 2 FIG 2 Connect Cable to Terminal Strip 37 12 TI14279a 7 Table 1 Terminal Strip Wire Connecti...

Page 5: ...s 5 7 6 7 5 Table 2 EFCM Terminal Connections Pin No Cable Wire Colors Pin No EFCM Connector 1 Black 1 6 2 White 2 6 3 Red 3 6 4 Green 4 6 5 Orange 9 7 6 Blue 10 7 7 White Black 11 7 8 Red Black 12 7...

Page 6: ...the switch es in the left side of the enclosure See FIG 4 2 Connect the wires from PS 1 to the right side of the terminal strip 12 pins 5 6 as indicated by the label 38 See FIG 5 and Table 1 3 If usi...

Page 7: ...izing air safety shutoff valve IN port See the gun flush box manual for details on the safety shutoff valve Connect Air Supply to Module Connect a 1 4 in 6 mm OD tube between a clean dry air supply fi...

Page 8: ...NAL rail mount 12 13 115671 CONNECTOR tube 1 4 in OD 1 14 C06061 MUFFLER sintered 1 8 diam 1 15 111328 CONNECTOR tube 5 32 in OD 2 16 SCREW machine truss hd 2 17 104640 GASKET 2 18 103832 SCREW machin...

Page 9: ...Dimensions 3A4497A 9 Dimensions TI14276a TI14278a 6 75 in 171 5 mm 7 50 in 190 5 mm 6 28 in 159 5 mm 4 00 in 101 6 mm 4 00 in 101 6 mm Mounting Holes...

Page 10: ...Dimensions 10 3A4497A...

Page 11: ...231 Air Control Module US Metric Maximum air inlet pressure 100 psi 0 7 MPa 7 bar Inlet Outlet Sizes Air inlet size 1 4 in 6 mm OD tube connector Air exhaust port size 5 32 4mm OD tube connector Weigh...

Page 12: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...