Repair
3A8571A
19
information
beginning on page 9.
Pump Housing Assembly P/N
133374
Disassembly
1. Follow
2. Turn off and disconnect the power to the pump.
3. Remove the pump from the tank.
4. Remove the suction tube from the pump.
5. Remove the four terminal box cover screws
. 18).
6. Pull the terminal box cover gently upward off of the
terminal box.
7. Remove the gasket.
8. Remove the pressure switch wires from the toggle
switch and relay terminal (F
9. Cut the pressure switch wire connectors off of the
pressure switch wires (F
F
IG
. 17
Grounding Wire
F
IG
. 18
F
IG
. 19
Terminal Box
Cover Screws
Pressure
Switch Wires
Toggle Switch and
Relay Terminal