Repair
20
3A8571A
10. Unscrew the strain relief nut (F
. 21).
11. Pull the pressure switch wires out of the terminal
box through the strain relief (F
12. Pull the pressure switch wires out of the wire clamp
13. Remove the four Allen screws (6) using a 5/16 in.
(8 mm) hex wrench (F
. 22).
14. Remove the pump housing assembly (F
F
IG
. 20
F
IG
. 21
Strain Relief
Strain Relief Nut
Wire Clamp
F
IG
. 22
F
IG
. 23
6
Motor
Pump Housing Assembly