Operation
12
3A8571A
Operation
NOTE: When the system is not in use, always turn the
power switch (K) (
located on the terminal box of the motor, off. Failure to
do so can result in a spill if a hose ruptures or a leak
occurs in the system plumbing. If a leak occurs, the
pressure in the system will drop, signaling the pump to
turn on.
See F
. 4, page 7 for reference numbers.
The on-demand dispensing pump turns on or off
depending upon the pump outlet pressure. When the
dispensing valve is open, the system pressure
decreases and the pump will begin pumping fluid.
When the dispensing valve is closed, the system
pressure increases and the pump will stop pumping
fluid.
1. Turn the power switch, located on the terminal box
of the motor, ON.
2. Place the outlet of the dispensing valve into the fill
container.
3. Open the dispensing valve to the full open position,
until the desired amount of fluid is dispensed.
4. Close the dispensing valve to stop dispensing.
Pressure Switch
The pressure switch (B) (
,
page 7) is factory set to 290 psi (2.00 MPa, 20.0 bar).
Once the pressure in the system reaches 290 psi (2.00
MPa, 20.0 bar), the pressure switch opens and stops
the motor (F
. 8).
Thermal Induced Pressure
Relief
The pump is equipped with a standard outlet check
valve (E) (
, page 7). If a
check valve with thermal relief is required, purchase PN
133097 and replace the standard check valve (F
. 8).
NOTICE
Do not operate the pump continuously more than 30
minutes in one (1) hour. Failure to follow these
instructions can result in damage to the pump.
F
IG
. 8