Setup
3A5581C
9
3.
Non-DCS Models:
Rotate Cutter Head Engage
Lever to upwards position to release lower linkage
from inner frame.
DCS Models:
Press the Home Button on the DCS
Control.
4. Turn the pressure control dial until the indicator is at
“0”. This releases tension from the pressure control
spring.
5. Unhook spring from the spring plunger (bottom rear
section of machine).
6. Rotate the inner frame upwards to gain access to
the cutters.
7. If there is a cutter head attached, it must be
removed. To do so, strike the cutters in a counter
clockwise direction with a rubberized mallet or wood
block.