Pressure Relief Procedure
12
312888D
Pressure Relief Procedure
1.
Close both manual valves.
2.
Set safety stop to OPEN.
3.
Trigger gun onto cardboard or into waste container
to relieve pressure.
4.
Release gun trigger, set safety stop to SERVICE
(CLOSED), and close manual valves.
Relieve pressure before cleaning or repairing gun.
If fluid in hose and proportioner is still under pressure,
follow Pressure Relief Procedure in your Proportioner
manual.
To relieve pressure in hose after gun is removed, place
fluid manifold over containers, facing away from you.
Very carefully open fluid valves. Under high pressure,
fluid will spray sideways from fluid ports.
Manual Valves