10. On each screw (29), place two belleville washers
(27), with the rounded side of first washer toward
the screw head and the rounded side of the
second washer away, then a flat #12 washer
(26). Thread each screw assembly through an
outlet manifold retainer (11) and into the fluid
cover (6), and tighten by hand for now.
11. Turn the pump over and insert a ball retainer
(20), check ball (22), d-ring (21), and o-ring (17)
into the inlet side of each fluid cover (6).
12. Align the inlet manifold (10) on the assembly.
Use the placement of dowel pins (23) to orient
the manifold so the inlet port is facing the correct
direction for your application.
13. Align the inlet manifold retainers (12) on the inlet
manifold (10).
14. On each screw (29), place two belleville washers
(27), with the rounded side of first washer toward
the screw head and the rounded side of the
second washer away, then a flat #12 washer
(26). Thread each screw assembly through an
inlet manifold retainer (11) and into the fluid
covers (6), and tighten by hand for now.
15. Follow
.
16. Replace all bolt covers (37).
334795F
23
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910