Replace Throat Packings
Note
The throat packings are available as a
preassembled kit.
Pump Part No.
Throat Seal Repair
Kit
24W152
24V752
24W153
24V753
24W150
24V752
24W151
24V753
1. Relieve the pressure. See
Pressure Relief Procedure, page 8
.
2. See Fig. 2. Unscrew the packing nut (2) using a
pipe wrench. Remove the o-ring (27) and washer
(26) from the bottom of the packing housing (25)
or from the outlet housing (3).
3. Place the flats of the packing nut (2) in a vise.
Unscrew the packing housing (25) and discard it
and the packings. Remove the washer (24), seal
(23), and backup washer (22) from the packing
nut.
4. The throat repair kit is preassembled. Screw the
kit into the packing nut (2), making sure that the
backup washer (22), seal (23), and washer (24)
are properly positioned on top of the packing
housing (25), with the lips of the seal facing
down. Torque the packing housing (25) to 225
±10 ft-lb (305 ± 14 N•m).
5. Before installing packing housing into pump,
generously lubricate seals with high temperature
grease supplied with repair kit.
6. If necessary, use an arbor press to install o-ring
(27) in packing housing (25).
7. Screw the packing nut (2) and packing housing
(25) into the outlet housing (3). Torque to 150 ±
30 ft-lb (203 ± 41 N•m).
Figure 2 Throat Packings
1
Torque to 225 ± 10 ft-lb (305 ± 14 N•m).
2
Torque to 150 ± 30 ft-lb (203 ± 41 N•m).
3
Lips of u-cup packing must face down.