Installation
334203A
7
Fluid Supply Hose
Install the fluid supply hose (E) fluid fitting into the pump
inlet snuggly.
Do not over-tighten.
NOTE:
At the inlet, if the fluid pressure is greater than
15 psi (0.1 MPa, 1 bar) the diaphragm life will be short-
ened.
Mounting Bracket (2) Installation
See Wall Mounting Kit 24F870 instructions (below) or
Drum Mounting Bracket 24V679 or 24V686 instructions,
page 7.
•
When installing bracket, be sure the mounting sur-
face can support the weight of the pump, hoses and
all accessories, as well as the stress caused during
operation.
•
On all installations mount the pump using screws
and nuts provided.
•
Always keep nozzle bath tray filled with water.
Wall Mounting Kit 24F870 (2): Models 24V677 and
24V678 only. For a list of Kit parts referenced in the
installation instructions, see page 12.
The Nozzle Holder and Mounting Bracket are also iden-
tified as items J and N on the Typical Installation Dia-
gram provided on page 4.
1. Determine location to install mounting plate (2f).
2. Use holes the plate (2f) as a template. Mark mount-
ing hole locations. Pre-drill mounting holes in
mounting surface.
3. Use screws (2a) to install plate (2f).
4. Align holes in nozzle holder bracket (2h) with holes
in plate (2f). Use screws (2b), nuts (2e) and wash-
ers (2d) to install meter tray plate.
5. Place nozzle bath (2g) in nozzle holder bracket (2h).
Fill bath with water.
Keep meter bath filled with
water at all times.
Drum Mounting Bracket (2): Model 24V679 or
24V686. For a list of Kit parts referenced in the
installation instructions, see page 12.
The Nozzle Holder and Drum Bracket are also identified
as item J and K on the Typical Installation Diagram pro-
vided on page 5.
1. Position drum mounting plate (2f) on top of drum.
2. Use screws (2b), nuts (2e) and washers (2d) to
install mounting plate to pump.
3. Align holes in nozzle holder bracket (2h) with holes
in plate (2f). Use screws (2b), nuts (2e) and wash-
ers (2d) to install meter tray plate.
4. Place nozzle bath tray (2g) in nozzle holder bracket
(2h). Fill bath with water.
Keep nozzle bath tray
filled with water at all times.
Pump (1)
Install pump (1) to mounting bracket (2). For complete
pump instructions refer to the pump instruction manual
included with your system.
•
If necessary, change the orientation of the fluid inlet
and outlet ports on the pump. See pump instruction
manual for this procedure.
•
Retorque bolts per specifications.
Suction Hose (8)
Install suction hose (8).
a. Slide two hose clamps to (11) over hose (8).
b. Install one end of hose (8) to dispense coupler
hose barb (included in the Inlet Suction Kit).
c. Tighten one hose clamp (11) over end of hose
(8) and dispense coupler hose barb (included in
the Inlet Suction Kit).
d. Install other end of hose (8) over barbed end of
fitting (17).
e. Tighten second hose clamp (11) over end of
hose (8) and barbed end of fitting (17).
f.
Install seal (14) on the 3/4 inch end of fitting
(15).