background image

Installation

5

6.

Replace and partially tighten both screws (B). You 
can now remove the breaker bar. Pull out a section 
of hose and allow it to retract to test the tension 
adjustment. 

7.

If additional tension is required, insert the breaker 
bar in the bracket again and remove screws (B). 
Then repeat steps 5 - 6.

8.

When you are satisfied with the new setting, tighten 
screws A and B.

Decreasing Spring Tension

(spring is too tight, hose retracts too fast)

1.

Loosen screw (A) 3-5 turns. Do not completely 
remove it.

2.

Use a hex wrench to loosen, the two screws (B). Do 
not completely remove them.

3.

Insert a 3/8” square drive breaker bar in opening (C) 
on the spring adjustment plate (D).

4.

While holding the breaker bar securely, completely 
remove the two screws (B).

5.

Firmly grasp the breaker bar with both hands and 
turn it counter-clockwise one turn at a time to 
decrease (loosen) spring tension. 

6.

Replace and partially tighten both screws (B). You 
can now remove the breaker bar. Pull out a section 
of hose and allow it to retract to test the tension 
adjustment. 

7.

If additional adjustment is required, insert the 
breaker bar in the bracket again and remove screws 
(B). Then repeat steps 5 and 6.

8.

When you are satisfied with the new setting, tighten 
screws A and B.

9.

Match holes (e) in end panel (403) to mating holes 
(f) in side panel. Install and tighten screws (402) to 
join the end and side panels together.

10. Clean and dry off surface of each end panel. Attach 

a Graco label (404) to the center of each end panel.

11. Position hose stop so hose extends far enough for 

all operators to reach dispensing valve. 