1.

Install hose stop (D) to end of hose. If hose has a 
warning tag, hose stop should be installed on the 
same end as the warning tag (F).

NOTE: 

If hose is equiped with a kink guard this end 

must be on the same end as the hose stop.

2.

Insert screws (aa) through hose stop (cc) and hand 
tighten nuts (bb) to hold hose stop in place.

3.

Run the end of hose (B), through the hose guide (G) 
and then the hole (E) in reel (F

IG

. 3)

4.

Insert hose end (B) through bracket (H). Attach 
hose end (B) to strain relief hose (J).

5.

Pull the hose hard (B) enough to release the latch 
and slowly allow the hose to retract.

6.

If used, re-assemble hose reel enclosure following 
the procedure described in your instruction manual 
included with your unit.

7.

Flush system.

 

To avoid contaminating the fluid with line-scale, 
chips or other installation debris, before installing 
meter or dispense valve to end of hose, flush the 
equipment with a compatible solvent such as Stod-
dard solvent or mineral spirits. 

a.

Secure the end of the hose in a waste bucket.

b.

Blow out entire lubricant supply line with air.

c.

Pump solvent through line until fluid runs clear 

and is debris free. 

d.

Pump lubricant through line until all solvent is 

flushed out.

8.

Position hose stop (D) so hose extends far enough 
for all operators to reach dispensing valve. Securely 
tighten nuts (bb) to keep hose stop in place.

9.

Install meter or dispense valve to end of hose follow-
ing instructions provided with the dispense equip-
ment. 

10. Adjust spring tension.

Adjusting Spring Tension

Increasing Spring Tension

(spring is too loose, hose does not retract completely or 
retraction is sluggish)

1.

Loosen screw (A) 3-5 turns. Do not completely 
remove it.

2.

Use a hex wrench to loosen, the two screws (B). Do 
not completely remove them.

3.

Insert a 3/8” square drive breaker bar in opening (C) 
on the spring adjustment plate (D).

4.

While holding the breaker bar securely, completely 
remove the two screws (B).

5.

Firmly grasp the breaker bar with both hands and 
turn it clockwise one turn at a time to increase 
(tighten) spring tension. 

F

IG

. 3

NOTICE

Do not bypass mounting bracket (H). Failure to attach 
the hose through mounting bracket (H) can cause 
decreased retraction performance.

C

B

D

E

G

F

J

H