Calibrate
Calibrate
Calibrate the
the
the Meter
Meter
Meter
NOTE:
NOTE:
NOTE: See
Setup Screen 4: Calibration, page 45
, for
further screen information, if needed.
When
When
When to
to
to Calibrate
Calibrate
Calibrate
• The first time the system is operated.
• Whenever new materials are used in the system,
especially if the materials have viscosities that
differ significantly.
• As part of regular maintenance to retain meter
accuracy.
• Whenever a flow meter is serviced or replaced.
Read
Read
Read Before
Before
Before Calibration
Calibration
Calibration
• Meter k-factor on
Setup Screen 4: Calibration, page 45
, is updated
automatically after the calibration procedure
is completed. You also may manually edit the
k-factor if desired.
• All values on this screen are in cc or cc/pulse,
regardless of the units set in the other Setup
screens.
• Before calibrating the meter, be sure the system
is primed with material.
• Disable alarms before calibration.
Calibration
Calibration
Calibration Steps
Steps
Steps
1.
Press
to enter Setup Mode.
2.
Press
to move to Setup Screen 4.
3.
Press
to enter the screen.
4.
Press
to begin the calibration.
5.
Dispense about 300–500 cc of material into a
graduated cylinder. The amount the system
measures will display in the measured volume
field
.
6.
Press
to end the calibration.
7.
Press
to get to the dispensed volume field
, then press
to enter the field. Enter
the amount of material in the cylinder.
8.
After the volume is entered, the system calculates
the new k-factor
and shows it on Setup
Screen 4.
NOTE:
NOTE:
NOTE: To clear the counter and begin the
calibration again, press
, move briefly to
another screen, then return to Setup Screen 4
and start over. If you press
without leaving
the screen, the counter will continue from where
it is, without clearing.
9.
Press
to exit the screen.
10. Press
to exit Setup Mode.
Set
Set
Set the
the
the Modbus
Modbus
Modbus Addresses
Addresses
Addresses
See Setup
Setup
Setup Screen
Screen
Screen 11
11
11. By default, the Modbus
is set to Off
. If you need the Modbus,
set the Modbus mode to SLAVE
.
The address value is between 1 and 247.
The modbus address corresponds to the
address of the ProControl 1KE Plus. See
Appendix A - Modbus Variable Map, page 81
, for
more information.
Update
Update
Update the
the
the Software
Software
Software
Software updates are installed using a software token
(PN 25B324). Manual 3A1244 will accompany any
necessary software updates. Follow all instructions
and warnings in Manual 3A1244 to update your
ProControl 1KE Plus software.
3A6948A
55