Installation
3A1299K
15
Install Chiller (customer
supplied)
The following instructions apply to tank modules
(24C317, 24D562, 24D564, 24D565) that include the
heat exchanger assembly (G).
NOTE: Graco does not supply the chiller assembly.
1. Connect incoming water to inlet heat exchanger
port.
2. Connect outgoing water to outlet heat exchanger
port.
3. Configure the advanced display module (ADM) for
the chiller option. See the HFR or VRM Setup-Oper-
ation manual for instructions.
Auto-Refill Installation:
customer supplied feed system
NOTE: The auto-refill assembly is not assembled
when shipped.
1. Empty tank (C).
2. Remove plug from top of tank.
3. Install auto-refill assembly in 3/4 npt port.
4. Connect hose (not supplied) to 1/2 npt port on mate-
rial valve.
5. Connect air lines from air valve (A) to material
valve (D).
6. Connect main air line to air valve.
F
IG
. 9: Heat Exchanger Assembly
Water Inlet
Water Outlet
ti16671a
F
IG
. 10: Tank Assembly
Material
Air Solenoid
Valve
Valve
Air Line
Air Valve
ti16668a