24G611 Stand Kit, for Meter-Based Systems
3A1325C
3
24G611 Stand Kit, for Meter-Based Systems
24G611 Kit Parts
NOTE: Stand parts are not sold separately.
Install the Cart
1.
See F
. 2. Assemble the two sides of the cart as
shown. The swivel casters with brake (804) must be
installed at the rear of the cart.
2.
Install the meter stand adapter (812) on the two
sides of the cart and secure with the screws (808),
washers (807), lockwashers (806), and nuts (805).
3.
Install the cart onto the ProMix 2KE frame (F) with
the tabs (T) on the outside of the frame posts.
Secure with the screws (808), washers (807), lock-
washers (806), and nuts (805).
Dimensions
Ref.
Description
Qty.
801
TUBE, cart
2
802
PLUG, tube
4
803
CASTER, cart
2
804
CASTER, swivel, with brake
2
805
NUT, hex
8
806
WASHER, lock
8
807
WASHER
16
808
SCREW, cap, hex hd‘
8
809
PLUG, button
4
810
NUT
4
811
WASHER
4
812
ADAPTER, meter stand
1
TI16570a
Ref. in. (mm)
A
70.42 (1789)
C
21.75 (553)
D
27.00 (686)
A
C
D
F
IG
. 2. 24G611 Stand Kit, for Meter-Based Systems
NOTICE
The kit is not designed to be shipped when assembled
to a system. Damage will occur.
TI16569a
807
807
808
801
802
804
803
809
810
811
806
805
F
T
812
808
807
807
806
805