Installation
4
3A1657A
3000 Series Flow Meter
1.
Perform HFR
Pressure Relief Procedure
. See
HFR operation manual for detailed instructions.
2.
Perform dispense valve
Pressure Relief Proce-
dure
. See dispense valve manual, page 2, for
detailed instructions.
3.
Verify all air, hydraulic, and material pressures have
been relieved before continuing.
4.
Perform HFR
Shutdown
procedure. See HFR oper-
ation manual for detailed instructions.
5.
If the flow meter is for the A (Red) side,
connect inlet
fitting (2) and outlet fitting (4) to the flow meter. See
F
If the flow meter is for the B (Blue) side,
connect
inlet fitting (3) and outlet fitting (5) to the flow meter.
See F
NOTE:
The connections for each side of the machine
are different sizes to prevent attaching the incorrect
hoses. The A (Red) side has the smaller connections.
6.
Connect the flow meter assembly to the fluid
manifold (A) on the HFR system as shown in F
7.
Connect the 3-pin connector (B) on the flow meter
data cable to the flow meter. See F
8.
Route the flow meter data cable as shown in F
9.
Connect the other end of the flow meter data cable
to the fluid control module installed in the electrical
enclosure.
If the data cable is for the A (Red) side flow meter,
connect to port 1 on the FCM. See F
If the data cable is for the B (Blue) side flow meter,
connect to port 2 on the FCM. See F
F
IG
. 1: Flow Meter Installed on Fluid Manifold --
A (Red) side shown
4 or 5
2 or 3
B
A
ti17012a
F
IG
. 2: Flow Meter Data Cable Routing
F
IG
. 3: Flow Meter Data Cable Connections
ti17013a
ti17014a