![Graco 24E512 Operation And Repair Manual Download Page 16](http://html1.mh-extra.com/html/graco/24e512/24e512_operation-and-repair-manual_2253085016.webp)
Setup
16
3A0232E
Setup
1.
Before first use
, flush the gun. The equipment was
tested with lightweight oil, which is left in the fluid
passages to protect parts. To avoid contaminating
your fluid with oil, flush the equipment with a com-
patible solvent before using the equipment. See
, page 23.
2.
Engage trigger lock.
3.
For guns with cutters,
install cutter:
a.
If necessary, use a crescent wrench to adjust
pivot (541) so that it is parallel to gun front end.
See
on page 40.
b.
If necessary, use a crescent wrench to adjust
pivot so that open end points to front of gun.
c.
Back out screws (630). See
d.
Install cutter onto pivot so glass feed holes are
on top.
e.
Tighten screws (630) to lock cutter in place.
f.
Adjust cutter dispensing angle and chute angle
as desired.
4.
For internal mix guns,
verify solvent knob (BD) is
adjusted to the fully closed position. See F
. 6 on
page 17.
5.
Attach gun connections as described in F
on page 52 for fitting
sizes.
6.
For internal mix guns,
prime the solvent line. Turn
solvent adjustment knob (BD) until solvent dis-
charges from the front of the gun. See F
page 17.
7.
For guns with cutters,
insert glass strands into
feed.
8.
For guns with cutters,
adjust anvil to blade ten-
sion:
a.
Release lockdown (AG). See F
b.
Adjust tension knob (AF) as desired.
c.
Tighten lockdown (AG).
d.
Perform test spray to verify proper cutting of
glass strands.
e.
Adjust tension as necessary.
9.
For external mix guns,
adjust AAC knob (BD) to
middle of possible range of movement. See F
on page 17.
10. Adjust AAC pressure on proportioner.
11. Perform test spray. Adjust system and gun settings
as necessary to get desired results.
NOTICE
To prevent material curing inside the gun, do not
trigger gun if solvent is not primed.