Spray Tip Selection Chart
34
3A0149C
RAC SwitchTips, for use with G40 RAC Air Cap, Continued
NOTE: All tips in the Spray Tip Selection Charts below
can be used with Model G40 guns equipped with RAC
air cap 24C921.
FFT Fine Finish RAC Spray Tips
Order desired tip, Part No. FFTxxx, where xxx = 3-digit number from matrix below.
WRX WideRAC Spray Tips
Order desired tip, Part No. WRxxxx, where xxxx = 4-digit number from matrix below.
*
Tips are tested in water.
❖
Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
Orifice Size in.
(mm)
* Fluid Output at
2000 psi (14.0 MPa, 140 bar)
fl oz/min (lpm)
❖
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
4 to 6
(150)
6 to 8
(200)
8 to 10
(250)
10 to 12
(300)
12 to 14
(350)
Spray Tip
0.008 (0.203) 8.8 (0.26)
208
308
0.010 (0.254) 13.9 (0.41)
210
310
410
510
0.012 (0.305) 19.9 (0.59)
212
312
412
512
612
0.014 (0.356) 27.0 (0.80)
214
314
414
514
614
Orifice Size
in. (mm)
* Fluid Output at
2000 psi (14.0 MPa, 140 bar)
fl oz/min (lpm)
❖
Maximum Pattern Width at 12 in. (305 mm)
24 in. (610 mm)
Spray Tip
0.021 (0.533)
60.5 (1.79)
1221
0.023 (0.584)
72.7 (2.15)
1223
0.025 (0.635)
85.9 (2.54)
1225
0.027 (0.686)
100.0 (2.96)
1227
0.029 (0.737)
115.6 (3.42)
1229
0.031 (0.787)
131.8 (3.90)
1231
0.033 (0.838)
149.4 (4.42)
1233
0.035 (0.889)
168.3 (4.98)
1235
0.037 (0.940)
187.9 (5.56)
1237
0.039 (0.991)
208.9 (6.18)
1239
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
where QT = fluid output (fl oz/min) from the above table for the selected orifice size.
P
Summary of Contents for 24C853
Page 23: ...Repair 3A0149C 23...