Spray Tip Selection Chart
3A0149C
33
AAF Fine Finish Pre-Orifice Spray Tips
Recommended for high finish quality applications at low and medium pressures. AAF tips have a pre-orifice that
assists in atomizing sheer thinning materials, including lacquers.
Order desired tip, Part No. AAFxxx, where xxx = 3-digit number from matrix below.
*
Tips are tested in water.
RAC SwitchTips, for use with G40 RAC Air Cap
NOTE: All tips in the Spray Tip Selection Charts below
can be used with Model G40 guns equipped with RAC
air cap 24C921.
NOTE: Tips are sometimes packaged with other promo-
tional parts intended for the airless market. Disregard
extra parts.
LTX RAC Spray Tips
Order desired tip, Part No. LTXxxx, where xxx = 3-digit number from matrix below.
*
Tips are tested in water.
❖
Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
Orifice Size
in. (mm)
* Fluid Output
fl oz/min (lpm)
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
at 600 psi
(4.1 MPa, 41 bar)
at 1000 psi
(7.0 MPa, 70 bar)
6 to 8
(200)
8 to 10
(250)
10 to 12
(300)
12 to 14
(350)
Spray Tip
0.011 (0.279)
9.5 (0.28)
12.5 (0.37)
310
410
510
610
0.013 (0.330)
12.0 (0.35)
16.0 (0.47)
312
412
512
612
0.015 (0.381)
16.0 (0.47)
21.0 (0.62)
414
514
614
0.017 (0.432)
20.0 (0.59)
26.5 (0.78)
416
516
616
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
where QT = fluid output (fl oz/min) at 600 psi from the above table for the selected orifice size.
P
Orifice Size in.
(mm)
* Fluid Output,
at 2000 psi
(14.0 MPa, 140 bar)
fl oz/min (lpm)
❖
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
2 to 4
(100)
4 to 6
(150)
6 to 8
(200)
8 to 10
(250)
10 to 12
(300)
12 to 14
(350)
14 to 16
(400)
16 to 18
(450)
18 to 20
(500)
Spray Tip
0.009 (0.229) 11.2 (0.33)
109
209
309
409
509
0.011 (0.279) 16.6 (0.49)
111
211
311
411
511
611
0.013 (0.330) 23.3 (0.69)
213
313
413
513
613
0.015 (0.381) 30.8 (0.91)
115
215
315
415
515
615
0.017 (0.432) 39.5 (1.17)
217
317
417
517
617
817
0.019 (0.483) 49.7 (1.47)
219
319
419
519
619
819
0.021 (0.533) 60.5 (1.79)
221
321
421
521
621
721
821
0.023 (0.584) 72.7 (2.15)
323
423
523
623
723
0.025 (0.635) 85.9 (2.54)
225
325
425
525
625
0.027 (0.686) 100.0 (2.96)
227
327
427
527
627
827
0.029 (0.737) 115.6 (3.42)
329
429
529
629
729
0.031 (0.787) 131.8 (3.90)
231
331
431
531
631
831
0.033 (0.838) 149.4 (4.42)
433
533
633
833
0.035 (0.889) 168.4 (4.98)
235
335
435
535
635
735
835
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
where QT = fluid output (fl oz/min) from the above table for the selected orifice size.
P
Summary of Contents for 24C853