![Graco 248187 Instructions Manual Download Page 4](http://html1.mh-extra.com/html/graco/248187/248187_instructions-manual_2252748004.webp)
Hydraulic Reactor Kit Installation
4
309969C
Hydraulic Reactor Kit Installation
Disassembly
1.
Turn main power OFF
. Disconnect power
supply.
2.
Relieve pressure, see Reactor operation manual.
3.
Wait for pump and fluid to cool.
NOTE: Use dropcloth or rags to protect Reactor and
surrounding area from spills.
4.
Remove old rupture disk assembly (D) from pump
fitting (N). See F
Assembly
Apply pipe sealant and PTFE tape to rupture disk
assembly (D) threads. See F
. 3. Install as shown for
applicable pump. Exhaust hole must be at bottom.
Read warnings in Reactor repair manual. To avoid
severe burns, wait for heaters and fluid to cool before
installing kit.
Using a wrench on the rupture disk red housing can
cause damage, resulting in a lower rupture pressure.
To tighten the rupture disk assembly (D), use a
wrench on the hex. Do not use a wrench on the red
housing.