CAUTION

Electrostatic discharges can damage components on

PC board. Use a ground strap when handling or

installing PC board.
Using configurations other than those specified at

right results in poor sprayer performance.

1. Follow

Pressure Relief Procedure.

2. Remove pressure control cover.
3. Remove PC board. See Manual 309674 for

procedure.

4.

If using Kits:

248178, 248179,

248180, 246378, 246379, 246380

Do not clip resistor if PC board is to be installed in

a 395 model sprayer.

Clip and remove resistor if PC board is to be

installed in a 495 model sprayer.

Do not clip resistor if PC board is to be installed in

a 595 model sprayer.

If using Kits:

287909, 287910

If installing PC board in 490 model sprayer, clip
and remove resistor B.

If installing PC board in 495 model sprayer, clip

and remove resistor A.

If installing PC board in 595 model sprayer, do not

clip resistors.

5. Install PC board. See Manual 309674 for

procedure.

6. Install cover.

Summary of Contents for 248178

Page 1: ...ection splash ing fluid or moving parts follow Pressure Relief Procedure whenever you D are instructed to relieve pressure D stop spraying D check or service any system equipment D or install or clean spray tip 1 Lock gun safety latch 2 Turn ON OFF switch to OFF 3 Unplug power supply cord 4 Unlock gun safety latch Hold metal part of gun firmly to grounded metal pail Trigger gun to relieve pressure...

Page 2: ...48180 ST Max II 490 Hopper 253011 ST Max II 490 249926 253012 253013 287910 ST Max II 495 249928 253014 249978 ST Max II 595 253015 249930 395 233963 246380 240 Europe 495 233957 234178 246380 595 234438 248180 ST Max II 490 249927 ST Max II 495 249929 249979 287910 ST Max II 595 249931 395 233972 246378 110 UK 495 233973 233975 246378 595 234436 248178 ST Max II 490 249935 ST Max II 495 249936 28...

Page 3: ...248179 248180 246378 246379 246380 Do not clip resistor if PC board is to be installed in a 395 model sprayer Clip and remove resistor if PC board is to be installed in a 495 model sprayer Do not clip resistor if PC board is to be installed in a 595 model sprayer If using Kits 287909 287910 If installing PC board in 490 model sprayer clip and remove resistor B If installing PC board in 495 model s...

Page 4: ... 2894 to identify the nearest distributor All written and visual data contained in this document reflects the latest product information available at the time of publication Graco reserves the right to make changes at any time without notice Original instructions This manual contains English Sales Offices Minneapolis International Offices Belgium Korea China Japan GRACO INC P O BOX 1441 MINNEAPOLI...

Reviews: