Install Hardware
4
309867G
10. Close Reactor cabinet.
9.
Insert wires (B, C) in top front terminals of fuse block
(F) at circuit breaker module. Tighten screws (S).
11. Drill holes as follows:
a.
For Electric Reactor, drill holes using bracket (4)
as template. Apply sealant (4c) to screw
threads. Mount with screws (4a) and nuts (4b).
TI2514a
F
C
B
S
TI3581a
ti3574A
4
b.
For Hydraulic Reactor, drill two holes exactly as
shown below. Be careful not to damage compo-
nents inside cabinet when drilling holes. Apply
sealant (4c) to screw threads. Mount bracket (4)
with screws (4a) and nuts (4b).
12. Connect Reporter cable to interface plug (D).
13. Reconnect power supply. Turn Reactor main power
ON
. Main screen will appear on Reporter,
see page 5.
Reporter is now ready to record data from Reactor,
see page 5. To download data, first Install Soft-
ware, page 7.
ti7998A
Two 3/16 in. (5 mm)
diameter mounting
holes
2.75 in.
(70 mm)
3.00 in.
(76 mm)
0.93 in.
(24 mm)
TI3575a
D
TI7999a
D
Electric Reactor
Hydraulic Reactor