- 6 -

6

307965

Operation

Never operate the meter with the black plastic
cover removed.  The cover protects the meter from
damage due to impact.  Meters are factory sealed
to keep moisture and dirt out.  See the 

Service

section before you service the meter.

CAUTION

To prevent line contamination, which can cause
equipment malfunction or damage, flush the lines
before you install this equipment in the system.

CAUTION

To Activate the Digital Display

Press the 

RESET

 key pad to clear the meter before

starting a new dispense cycle.  This is the best way to
activate the meter, because it also clears the quantity
of the last dispense cycle.

The digital display can also be activated by pressing
the 

TOTAL 

key pad or by running fluid through the

meter.  See Fig. 2.

NOTE:

 The digital display of the meter goes blank

after approximately two minutes of non-use.

Function of TOTAL

When the digital display is blank, press and release the

TOTAL

 key pad to display the quantity of the last

dispense cycle.  See Fig. 3.

To see the accumulated total of fluid dispensed
through the meter, press and hold the 

TOTAL 

key pad.

The accumulated total is shown in gallons for the
gallon/quart/pint meter, and in liters for liter meter.  The
meter can accumulate a running total of up to 19,999
gallons (or liters) dispensed before returning to zero.
See Fig. 4.

Function of RESET

Press the 

RESET

 key pad to clear the quantity of the

last dispense cycle and return the digital display to all
zeros.  See Fig. 2.

To Change the Measurement Units 

(gallon/quart/pint meter only)

The meter is factory-set to dispense in quarts.  To
change the measurement units, press and hold the

RESET

 key pad until the measurement unit on the

right side of the digital display is flashing.  Then press
the 

TOTAL

 key pad until the desired measurement unit

is shown.  Release both key pads.  See Fig. 5.

To be sure the proper amount of fluid is dispensed,
always use the same measurement unit for a
particular fluid.Units should be changed only by
authorized employees.

CAUTION

To Verify the Accuracy of an Electronic
Meter

1.

Use a clean, calibrated container. If using a single
container, be sure to clean it after each dispense.

2.

Have pump air pressure at the lowest possible
setting for dispensing fluid.

3.

Put the tip of the nozzle at the bottom of the
calibrated container.

4.

If the tip of the dispense valve does not reach the
bottom of the calibrated container, use a length of
plastic tubing over the tip of the nozzle to ensure
liquid enters the container from the bottom.

5.

Trigger the gun slowly so the fluid immediately
covers the tip of the dispense valve.

6.

Dispense 1 quart of fluid according to the metered
display on the dispense valve.

7.

Allow product to sit for 20 minutes, then compare
the actual, physical measurement in the calibrated
container to the measurement displayed on the
meter.

NOTE: 

The procedure above will determine if the

meter is accurately dispensing the product and mini-
mize testing errors. Some variance may occur depend-
ing on the viscosity of the fluid. If this procedure deter-
mines that the meter is not accurate, recalibrate the
meter as described in the service manual or replace
the meter or the electronics as necessary.

Summary of Contents for 244075

Page 1: ...0 psi 10 3 MPa 103bar Maximum Working Pressure FOR USE WITH PETROLEUM BASED LUBRICANTS ONLY 244075 Measures in gallons quarts and pints 244076 Measures in liters Meter is factory set in quarts Table of Contents Warnings 2 Installation 5 Operation 6 Troubleshooting 8 Service 9 Parts 10 Accessories 11 Technical Data 11 Warranty 12 Graco Phone Number 12 307965T 02171 Parts ...

Page 2: ...ely D Do not exceed the maximum working pressure of the lowest rated system component Refer to the Technical Data on page 11 for the maximum working pressure of this component D Use fluids and solvents that are compatible with the equipment wetted parts Refer to the Tech nical Data section of all equipment manuals Read the fluid and solvent manufacturer s warn ings D Do not use 1 1 1 trichloroetha...

Page 3: ...rt of the body D Do not put your hand or fingers over the end of the dispensing valve D Do not stop or deflect leaks with your hand body glove or rag D Use only extensions and no drip tips that are designed for use with your dispensing valve D Do not use a low pressure flexible nozzle with this equipment D Follow the Pressure Relief Procedure on page 8 before cleaning checking or servicing the equ...

Page 4: ... 4 4 307965 Notes ...

Page 5: ...l lation shown is only a guide for selecting and installing an in line meter It is not an actual system design Contact your Graco representative for assistance in designing a system to suit your needs Fig 1 A B C KEY A In line meter B In line strainer C Shutoff valve D Pressure relief valve E Check valve F Bleed off valve 2251 D E F ...

Page 6: ... Units gallon quart pint meter only The meter is factory set to dispense in quarts To change the measurement units press and hold the RESET key pad until the measurement unit on the right side of the digital display is flashing Then press the TOTAL key pad until the desired measurement unit is shown Release both key pads See Fig 5 To be sure the proper amount of fluid is dispensed always use the s...

Page 7: ...n dispensing 1 gallon or less Always press the RESET key pad to clear the meter before a new dispense cycle QTS PTS PINTS QUARTS GALLONS GAL GAL GAL GRACO Press RESET to clear TOTAL RESET EXAMPLE OF ACCUMULATED TOTAL DIGITAL DISPLAY EXAMPLE OF MEASUREMENT UNITS Fig 2 Fig 3 Fig 4 QTS Fig 5 EXAMPLE OF TOTAL FOR LAST DISPENSE CYCLE ...

Page 8: ...ssure 3 Open any bleed type master air valves and fluid drain valves in the system 4 Leave the drain valve open until you have com pleted repairs and are ready to pressurize the system NOTE Before you check or repair the meter be sure all other valves controls and the pump are operating properly Problem Cause Solution Digital display does not activate Electronic control is malfunctioning Replace t...

Page 9: ...1 Relieve the pressure WARNING To reduce the risk of serious injury when you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 2 Attach the disposable grounding wrist strap to your wrist Connect the adhesive backed copper foil at the other end to any convenient electrical ground such as the grounding screw or metal case of a grounded electrical outlet 3 Lift ...

Page 10: ...09137 O RING 1 6 112093 SCREW 6 Model 244076 Liter Includes replaceable items 1 3 4 and 6 Ref No Part No Description Qty 1 191782 COVER 1 2 METERING UNIT liter 1 cannot be ordered separately 3 235901 ELECTRONIC CONTROL liter 1 4 109137 O RING 1 6 112093 SCREW 6 Replacement screws and o rings are included with item 3 WARNING Use only genuine Graco replacement parts This could result in a failure wh...

Page 11: ...ctory set in quarts Display shows quantity in 0 01 increments up to 199 99 gallons quarts or pints Totalizes in gallons or liters up to 19 999 units Inlet and outlet 1 2 npt non directional flow Operating temperature range 4_ F to 130_ F 20_ C to 55_ C Storage temperature range 40_ F to 140_ F 40_ C to 60_ C Battery specifications Rated discharge current 100 microamps Rated capacity 1 0 amp hour M...

Page 12: ...e purchaser s sole and exclusive remedy and are in lieu of any other warranties express or implied including warranty of merchantability or warranty of fitness for a particular purpose and of any non contractual liabilities including product liabilities based on negligence or strict liability Every form of liability for direct special or consequential damages or loss is expressly excluded and deni...

Reviews: