background image

2          309108

Remove the Battery

NOTE: Reference numbers in the text correspond to
the numbers in the Informer manual 309102.

Remove the battery, using the following applicable
procedure.

WARNING

FIRE AND EXPLOSION HAZARD
To reduce the risk of fire or explosion:

D

Do not remove or install the battery in a hazard-
ous location.

D

The internal and external ground wires for the
display must be correctly connected.

D

For a Display Assembly Mounted on the Meter

1.

Remove the display mounting screws (35) and the
external ground wire (44) from the sensor (31). Pull
the sensor out of the lower housing (11). Refer to
Fig. 1.

9633A

35 or 54

12

31 or 51

44 or 64

11

1

Fig. 1

2.

Remove the screw (43) and disconnect the internal
ground wire (9a) from the sensor (31). See Fig. 2.

3.

Unplug the connector (9) from the sensor circuit
board by pressing the connector latch (B), then
pulling the connector off the receptacle (C).

4.

Move the display assembly (A) to a non-hazardous
location.

5.

Remove the four screws (12) and remove the
display assembly lower housing (11).

6.

Remove the one screw (8a) that secures the cover
(7) and internal ground wire (9b) to the battery (3).

9

A

11 (Ref)

3

B

C

9a

43

31 (Ref)

Display Assembly to Mount on Meter

9b

8a (Ref)

6

Fig. 2

9631A

7

Reviews: