Installation/Operation

How to Use the Gun

1. Connect a grounded fluid hose to the gun inlet.

See Fig. 2

2. With no tip installed, start the pump. Flush the

pump according to the instructions supplied with it.
Prime the system with the fluid.

3. Follow the 

Pressure Relief Procedure

 on 

page 5. Be sure the gun trigger safety is en-
gaged. See Fig. 1.

4. Graco Flat Tip Style Dripless

 Guard

Install the tip (A) and the gasket (B) in the nut of
the tip guard (C). Screw the assembly firmly onto
the gun. Tighten the assembly with a wrench. See
Fig. 2.

NOTE:

 If the gasket (B) is not installed, the gun

will leak.

5. Reverse-A-Clean (RAC) IV Model 238–352

Install the RAC IV SwitchTip (40) and the tip guard
(41). See manual 308–644, supplied. See Fig. 2.

Fig. 2

06047

41

C

A

B

40

6. Start the pump. Adjust the fluid pressure until the

spray is completely atomized. Use the lowest
pressure necessary to get the desired results.
Higher pressure may not improve the spray pattern
and will cause premature tip wear and pump wear.

7. If adjusting the pressure does not give a good

spray pattern, follow the 

Pressure Relief Proce-

dure

 on page 5 and then try another tip size.

8. Use a full-open, full-close triggering action. Hold

the gun about 12 in. (350 mm) from and at right
angles to the work surface. Don’t swing the gun in
an arc. Practice to find the best length and speed
of stroke.

How to Adjust the Spray Pattern

1. To adjust the spray pattern direction, follow the

Pressure Relief Procedure

 on page 5. Loosen

the tip guard retaining nut (B). Turn the tip guard/
tip groove horizontally (C) for a horizontal pattern
and vertically (A) for a vertical pattern. Tighten the
nut. See Fig. 3.

2. The spray tip orifice and spray angle determines

the coverage and size of pattern. When more
coverage is needed, use a larger spray tip rather
than increasing fluid pressure.

CAUTION

The openings in the tip guard reduce paint buildup on
the tip guard while spraying. Any damage to the
sharp edges of the openings causes paint to collect
at that area. Never hang the gun by the tip guard.

KEY

A

Tip guard shown in position for

vertical spray pattern

B

Retaining nut

C

Tip guard shown in position for

horizontal spray pattern

Fig. 3

06050

A

B

C

A

Summary of Contents for 238-352

Page 1: ...KEEP FOR REFERENCE Contractor ST Airless Spray Gun 3600 psi 252 bar MAXIMUM WORKING PRESSURE Model 238 352 Series A Includes RAC DripLess Guard 515 size SwitchTip and 4 finger trigger GRACO INC P O B...

Page 2: ...purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum workin...

Page 3: ...you stop spraying Follow the Pressure Relief Procedure on page 5 if the spray tip clogs and before cleaning checking or servicing the equipment Tighten all fluid connections before operating the equip...

Page 4: ...n the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any light switch in the spray area while operating or if fumes are pr...

Page 5: ...re must be manually relieved to prevent the system from starting or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an i...

Page 6: ...If adjusting the pressure does not give a good spray pattern follow the Pressure Relief Proce dure on page 5 and then try another tip size 8 Use a full open full close triggering action Hold the gun a...

Page 7: ...ith Standard Flat Tip and Guard 1 Lock the gun trigger safety open the pressure drain valve CAUTION Never soak the entire gun in solvent Prolonged exposure to solvent can ruin the packings 2 Remove th...

Page 8: ...and spray tip 3 Start the sprayer and adjust it to the lowest pressure 4 Aim the gun into a grounded metal pail while holding it firmly to the pail Trigger the gun If the fluid emitted is not diffused...

Page 9: ...Soak and clean the parts 3 Put the pump intake in a grounded pail of water or solvent 4 Start the pump at its lowest pressure 5 Trigger the gun into the original pail When water or solvent appears rel...

Page 10: ...20 25 ft lb 27 34 N m 4 If the gun handle 6 was removed hand tighten it into the fluid housing 26 it should fit easily 5 Adjust the needle before using the gun Procedure below 6 Be sure the trigger g...

Page 11: ...ent 4 Remove swivel 15 guard retainer 42 and cushion o ring 43 5 Save guard retainer and cushion o ring 05968 Fig 10 6 12 42 43 15 Reassembly 1 Clean internal thread of handle 6 2 Install guard retain...

Page 12: ...12 308 664 Parts Drawing 06045 41 40 12 5 42 16 20 18 21 22 23 26 32 37 1 31 33 1 Included with 1 Model 238 352 Series A 1 Purchase separately 1 1 6 43 15 44 17...

Page 13: ...ENT 1 standard 50 mesh 20 179 763 SPRING 1 21 179 722 SPRING RETAINER color coded blue for standard 50 mesh filter 1 22 179 733 GASKET 1 23 191 244 END CAP 1 26 190 973 FLUID HOUSING 1 31 105 334 LOCK...

Page 14: ...ds is included with every Graco airless gun 237 859 RACR DripLesst Guard Order SwitchTip separately See your distributor for available sizes 220 222 Standard DripLesst Tip Guard Order flat tip separat...

Page 15: ...470g Inlet 1 4 npsm m swivel Maximum Material Temperature 120 F 50 C Sound Data Sound Pressure Level 78 dB A Sound Power Level 87 dB A Measured while spraying waterbase paint gravity 1 36 through a 51...

Page 16: ...uipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable ch...

Reviews: