Operation

Pressure Relief Procedure

WARNING

SKIN INJECTION HAZARD

Fluid under high pressure can be in-

jected through the skin and cause

serious injury. To reduce the risk of an

injury from injection, splashing fluid, or moving

parts, follow the

Pressure Relief Procedure

whenever you:

D

are instructed to relieve the pressure,

D

stop spraying,

D

check or service any of the system equipment,

D

or install or clean the spray tips.

1. Lock the spray gun trigger safety.
2. Shut off the air to the pump.
3. Close the bleed-type master air valve (required in

your system).

4. Unlock the gun trigger safety.
5. Hold a metal part of the gun firmly to the side of a

grounded metal pail, and trigger the gun to relieve

pressure.

6. Lock the spray gun trigger safety.
7. Open the drain valve (required in your system),

having a container ready to catch the drainage.

8. Leave the drain valve open until you are ready to

spray again.

If you suspect that the spray tip or hose is completely

clogged, or that pressure has not been fully relieved

after following the steps above, very slowly loosen the

tip guard retaining nut or hose end coupling and relieve

pressure gradually, then loosen completely. Now clear

the tip or hose.

WARNING

Moving parts can pinch or amputate your fingers or

other body parts. When air is supplied to the motor,

the air motor piston (located behind the air motor

plates) moves. See Fig. 2. Therefore, never oper-

ate the pump with the air motor plates removed.

Flush the Pump Before Using

The pump is tested with lightweight motor oil, which is

left in to protect the pump parts. If the fluid you are

using may be contaminated by the oil, flush it out with

a compatible solvent before using the pump. If the

pump is being used to supply a circulating system,

allow the solvent to circulate until the pump is thor-

oughly flushed.

WARNING

FIRE AND EXPLOSION HAZARD

For your safety, read the section

FIRE

AND EXPLOSION HAZARD

on page 4

before flushing and follow all the recom-

mendations given there.

Summary of Contents for 224348

Page 1: ...r table of contents Model 224348 Series C 10 1 Ratio Presidentr Pump Model 256713 Series A 10 1 Ratio Presidentr Pump 1 5 in Female Inlet 1800 psi 12 4 MPa 124 bar Maximum Fluid Working Pressure 180 p...

Page 2: ...y for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Rep...

Page 3: ...trigger safety operates before spraying dispensing D Lock the gun valve trigger safety when you stop spraying dispensing D Follow the Pressure Relief Procedure on page 9 whenever you are instructed to...

Page 4: ...including solvent rags and gasoline D Electrically disconnect all equipment in the spray dispense area D Extinguish all open flames or pilot lights in the spray dispense area D Do not smoke in the sp...

Page 5: ...and Clamp 2 Air and fluid hoses use only electrically conductive hoses with a maximum of 500 ft 150 m combined hose length to ensure grounding continuity 3 Air compressor follow manufacturer s recomme...

Page 6: ...ump Air Regulator F Air Line Filter G Bleed Type Master Air Valve for accessories H Air Supply Hose J Fluid Drain Valve required K Fluid Filter L Fluid Supply Hose M Spray Gun N Pump Bung Adapter Y Gr...

Page 7: ...s vent plug to prevent a vacuum from forming in the drum Air and Fluid Hoses Be sure all air and fluid hoses are properly sized and pressure rated for your system Use only electrically conductive air...

Page 8: ...8 308118 Notes...

Page 9: ...y to spray again If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining...

Page 10: ...ause pre mature wear of the packings and spray tip WARNING To reduce the risk of overpressurizing your system which could result in component rupture and cause serious injury never exceed the Maximum...

Page 11: ...11 308118 Operation Fig 2 AIR MOTOR PLATE 14 0200A...

Page 12: ...12 308118 Notes...

Page 13: ...sup ply Clear increase air supply Insufficient air pressure closed or clogged air valves etc Open clean Exhausted fluid supply Refill purge all air from pump and fluid lines Clogged fluid line valves...

Page 14: ...acement rod 1 Orient the pump s fluid outlet R to the air motor s air inlet S as was noted in step 2 under Disconnecting the Displacement Pump Position the displace ment pump 101 on the tie rods 102 S...

Page 15: ...ons on how to verify correct orientation see NOTE in step 7 on page 16 5 Loosen the packing nut 14 then pull the dis placement rod 1 and connecting rod 8 out the bottom of the outlet housing 5 6 Secur...

Page 16: ...ealant to the male threads of the adapter 10 Screw the piston mounting stud 13 onto the connecting rod adapter 10 and torque to 50 70 ft lb 68 95 NSm 5 Place the flats of the displacement rod 1 in a v...

Page 17: ...2 3 25 3 4 LIPS OF V PACKINGS MUST FACE DOWN 5 SEE DETAIL B 5 6 7 15 8 1 9 11 12 17 18 19 21 16 27 13 10 20 1 2 Apply sealant and torque to 50 70 ft lb 68 95 NSm 1 1 1 Apply thread lubricant 2 2 2 DET...

Page 18: ...See pages 20 and 21 for parts 1 102 166237 ROD tie stainless steel 3 5 89 mm shoulder to shoulder 3 105 156082 SEAL o ring nitrile rubber 1 106 207352 AIR MOTOR See manual 306982 for parts 1 107 15825...

Page 19: ...DISPLACEMENT PUMP ASSY 1 5 in female inlet See pages 20 and 21 for parts 1 102 24B189 ROD tie stainless steel 3 5 89 mm shoulder to shoulder 3 105 156082 SEAL o ring nitrile rubber 1 106 205997 AIR MO...

Page 20: ...acement Pump Model 256712 Series A Severe Duty Stainless Steel Displacement Pump 1 5 in Female Inlet Includes items 1 34 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 25 26 28 29 30 31 3 13 27 30...

Page 21: ...6 V PACKING throat PTFE 2 26 176634 WASHER piston stainless steel 1 27 186993 STUD piston stainless steel 1 28 186990 GLAND piston male stainless steel 1 29 176635 V PACKING piston PTFE 2 30 176638 V...

Page 22: ...Fluid flow at 60 cpm 3 gallon 11 4 liters Recommended speed for optimum pump life 15 25 cycles min 0 75 1 25 gpm 2 84 to 4 73 liters min Air consumption approx 15 scfm 0 42 m3 min at 1 gpm 3 8 liters...

Page 23: ...a 12 5 bar 180 psi air pressure B 0 7 MPa 7 bar 100 psi air pressure C 0 49 MPa 4 9 bar 70 psi air pressure D 0 28 MPa 2 8 bar 40 psi air pressure 1 4 14 D Air Consumption Chart 0 20 40 60 80 100 0 1...

Page 24: ...flow at 60 cpm 2 5 gallon 9 46 liters Recommended speed for optimum pump life 15 25 cycles min 0 63 1 04 gpm 2 38 to 3 94 liters min Air consumption approx 8 2 scfm 0 23 m3 min at 1 gpm 3 8 liters mi...

Page 25: ...0 7 MPa 7 bar 100 psi air pressure C 0 49 MPa 4 9 bar 70 psi air pressure D 0 28 MPa 2 8 bar 40 psi air pressure 1 4 14 D Air Consumption Chart 0 8 16 24 32 40 0 1 2 3 4 5 PUMP DELIVERY Test Fluid No...

Page 26: ...0 in 42 68 in 1379 mm 295 mm 1084 mm 256714 55 16 in 11 60 in 43 56 in 1401 mm 295 mm 1106 mm Model 224348 Shown A C Model 224348 3 8 npsm f Model 224350 3 8 npt f AIR INLET 3 4 npt f FLUID OUTLET B 0...

Page 27: ...27 308118 Notes...

Page 28: ...t sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco mak...

Reviews: