23
308118
Technical Data (10:1 President)
Fluid Outlet Pressure Chart
0
200
400
600
800
1000
1200
1400
1600
1800
0
1
2
3
4
5
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
PUMP
OUTLET
P
RESSURE
100
20
40
60
CPM
80
3.8
7.6
11.4
15.2
19.0
GPM
l/min
A
B
C
7.0, 70
4.2, 42
PSI
5.6, 56
2.8, 28
8.4, 84
11.0, 110
MPa, BAR
9.6, 96
12.5, 125
To find Outlet Pressure
(MPa/bar/psi) at a specific
delivery (liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected fluid outlet pressure curve.
Curve slopes from left to right.
Follow left to scale and read outlet pressure.
A
1.25 MPa, 12.5 bar (180 psi) air pressure
B
0.7 MPa, 7 bar (100 psi) air pressure
C
0.49 MPa, 4.9 bar (70 psi) air pressure
D
0.28 MPa, 2.8 bar (40 psi) air pressure
1.4, 14
D
Air Consumption Chart
0
20
40
60
80
100
0
1
2
3
4
5
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
AI
R
CONSUMPTI
ON
20
40
60
80
CPM
100
3.8
7.6
11.4
15.2
19.0
GPM
l/min
2.800
CFM
m
3
/min
0.56
1.12
1.68
A
B
C
To find Pump Air Consumption
(m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected air consumption curve.
Curve slopes from right to left. Follow left to
scale and read air consumption.
A
1.25 MPa, 12.5 bar (180 psi) air pressure
B
0.7 MPa, 7 bar (100 psi) air pressure
C
0.49 MPa, 4.9 bar (70 psi) air pressure
D
0.28 MPa, 2.8 bar (40 psi) air pressure
D
2.240
Summary of Contents for 224348
Page 8: ...8 308118 Notes...
Page 11: ...11 308118 Operation Fig 2 AIR MOTOR PLATE 14 0200A...
Page 12: ...12 308118 Notes...