background image

12

308116

Service

Disconnecting the Displacement Pump

1.

Flush the pump if possible. Stop the pump at the
bottom of its stroke. Follow the Pressure Relief
Procedure 
on page 8.

2.

Disconnect the air and fluid hoses. Remove the
pump from its mounting. Note the relative position
of the pump’s fluid outlet (R) to the air motor’s air
inlet (S).

3.

Unscrew the tie rod locknuts (102) from the tie
rods (103). Remove the cotter pin (111). Unscrew
the displacement rod (13) from the air motor (108).
Carefully pull the displacement pump (101) off the
air motor (108). Inspect the o-ring (110). See Fig 4.

4.

Refer to page 13 for displacement pump service.
To service the air motor, refer to the separate air
motor manual (306982 or 307043), supplied.

Reconnecting the Displacement Pump

1.

Lubricate the o-ring (110) and check that it is in
place on the displacement rod (13). Orient the
pump’s fluid outlet (R) to the air motor’s air inlet
(S) as was noted in step 2 under Disconnecting
the Displacement Pump. 
Position the displace-
ment pump (101) on the tie rods (103). See Fig 4.

2.

Screw the locknuts (102) onto the tie rods (103)
loosely. Screw the displacement rod (13) into the
shaft of the air motor (108) until the pin holes in
the rod and shaft align. Install the cotter pin (111).

3.

Apply thread sealant to the pump fluid outlet (R)
and the threads of the fluid hose. Mount the pump
and reconnect all hoses. Reconnect the ground
wire if it was disconnected during repair.  Tighten
the packing nut/wet-cup (2) so it is just snug – no
tighter. Fill the wet-cup with Graco Throat Seal
Liquid or compatible solvent.

4.

Tighten the tie rod locknuts (102) evenly, and
torque as shown in Fig 4.

5.

Start the pump and run it at about 40 psi (0.3 MPa,
2.8 bar) air pressure, to check that it is operating
properly.

6.

Check for fluid leakage at the packing nut/wet-cup
(2). Follow the Pressure Relief Procedure on
page 8 before tightening the packing nut/wet-cup.

Fig. 4

103

110

Model 224342 Shown

0194

108

111

101

102

13

2

R

S

1

3

2

1

3

2

2

Lubricate.

Model 224342: Torque to 20–30 ft-lb (27–41 N

m).

Models 224343, 902147, 247147: Torque to 10–15 ft-lb
(14–20 N

m).

Apply sealant, as required.

Summary of Contents for 224342

Page 1: ...bar Maximum Fluid Working Pressure 120 psi 0 8 MPa 8 4 bar Maximum Air Input Pressure UHMWPE PTFE PACKED PUMPS Model No 261630 Series A PTFE PACKED PUMPS Model No 247147 Series A Model No 902147 Seri...

Page 2: ...use the equipment to rupture or malfunction and result in serious injury This equipment is for professional use only Read all instruction manuals tags and labels before operating the equipment Use the...

Page 3: ...ion weekly Refer to the gun manual Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 8 if the spra...

Page 4: ...ee of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do...

Page 5: ...pump E Pump Air Regulator F Air Line Filter G Bleed Type Master Air Valve for accessories H Air Supply Hose J Fluid Drain Valve required K Fluid Filter L Fluid Supply Hose M Spray Gun N Fluid Suction...

Page 6: ...slot in lug Z and tighten the locknut securely See Fig 2 Con nect the other end of the wire to a true earth ground To order a ground wire and clamp order Part No 222011 Fig 2 W Y X Z 0720 2 Air and fl...

Page 7: ...onnect a grounded fluid hose L to the pump s fluid outlet Connect a fluid suction hose N to the pump s 3 4 npt f fluid intake Use a grounded 1 2 in I D minimum air hose H to supply air to the pump Air...

Page 8: ...in valve open until you are ready to spray again If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowl...

Page 9: ...mature wear of the pump packings and spray tip WARNING To reduce the risk of overpressurizing your system which could result in component rupture and cause serious bodily injury NEVER exceed the maxim...

Page 10: ...10 308116 Operation Maintenance Fig 3 Air Motor Plate 2 0195...

Page 11: ...air pressure closed or clogged air valves etc Open clean Exhausted fluid supply Refill purge all air from pump and fluid lines Clogged fluid line valves etc Clear Packing nut 2 too tight Loosen see pa...

Page 12: ...acement Pump Position the displace ment pump 101 on the tie rods 103 See Fig 4 2 Screw the locknuts 102 onto the tie rods 103 loosely Screw the displacement rod 13 into the shaft of the air motor 108...

Page 13: ...he part up to the light at an angle Be sure the ball seats of the piston 26 and intake valve housing 15 are not chipped or nicked Replace any worn or damaged parts Reassembly NOTE On UHMWPE PTFE packe...

Page 14: ...ckings must face up 28 26 19 27 20 25 4 12 7 15 9 8 21 See Detail B 1 10 13 2 See Detail A Detail B Piston Packings 6 3 28 26 2 14 24 or 5 5 11 NOTE Lips of v packings must face down 1 Detail A Throat...

Page 15: ...EMENT PUMP ASSY See pages 18 19 for parts 1 102 102021 NUT lock 3 8 16 stainless steel 3 103 166237 ROD tie stainless steel 3 5 in 89 mm shoulder to shoulder 3 108 207352 AIR MOTOR See 306982 for part...

Page 16: ...DISPLACEMENT PUMP ASSY for Model 224343 only See pages 18 19 for parts 1 254999 DISPLACEMENT PUMP ASSY for Model 261630 only See pages 18 19 for parts 1 102 102021 NUT lock 3 8 16 stainless steel 3 10...

Page 17: ...15G976 DISPLACEMENT PUMP ASSY See pages 20 21 for parts 1 102 102021 NUT lock 3 8 16 sst 3 103 24B189 KIT tie rod 3 108 205997 AIR MOTOR See 307043 for parts 1 110 156082 SEAL o ring nitrile rubber 1...

Page 18: ...placement Pump Includes items 1 31 Model 254999 Series A Severe Duty UHMWPE PTFE Packed Stainless Steel Displacement Pump Includes items 1 33 2 14 5 11 1 10 13 21 3 28 19 27 20 25 4 224341 only 33 254...

Page 19: ...G valve intake stainless steel 224341 only 1 15J574 HOUSING valve intake 254999 only 1 19 176634 WASHER piston stainless steel 1 20 176635 V PACKING piston PTFE 2 21 176637 PIN ball stop piston stainl...

Page 20: ...20 308116 Parts Model 15G976 Series A Severe Duty PTFE Packed Stainless Steel Displacement Pump Includes items 1 31 2 14 5 11 1 10 13 21 3 28 19 27 20 25 26 8 9 4 12 15 7 6 0190C 31 4...

Page 21: ...1 10 164782 O RING PTFE 1 11 186987 GLAND throat male stainless steel 1 12 164846 O RING PTFE 1 Ref No Part No Description Qty 13 24C506 ROD displacement stainless steel1 14 186988 GLAND throat femal...

Page 22: ...4 15 2 liters min gpm FLUID FLOW TEST FLUID NO 10 MOTOR OIL To find Fluid Outlet Pressure bar psi at a specific fluid flow lpm gpm and operating air pressure bar psi 1 Locate desired flow along botto...

Page 23: ...3 8 7 6 11 4 15 2 liters min gpm FLUID FLOW TEST FLUID NO 10 MOTOR OIL To find Fluid Outlet Pressure bar psi at a specific fluid flow lpm gpm and operating air pressure bar psi 1 Locate desired flow...

Page 24: ...f AIR INLET 0195 Pump Model A B C 224342 28 38 in 721 mm 14 63 in 372 mm 13 75 in 349 mm 224343 902147 247147 25 25 in 641 mm 11 5 in 292 mm 13 75 in 349 mm 261630 26 25 667 mm 14 63 372 mm 13 75 in...

Page 25: ...308116 25 Notes...

Page 26: ...ts lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Gra...

Reviews: