14 307-488
Accessories
For Two Gun Systems
Each line in a two gun system must have a shutoff
valve to relieve fluid pressure if the fluid line becomes
clogged, and to isolate one gun for servicing while the
other is in operation. Director valve 214–711 is recom-
mended for both purposes. Use elbow 100–840 to
direct the outlet flow from the drain valve in a safe
direction to a waste container. Use reducer bushings
100–176 and 100–206 to connect the valve to the
outlets of fluid filter 214–625.
In the draining mode, the valve handle is turned away
from the elbow (marked DRAIN on the valve housing);
in the operating mode, the handle is turned toward the
elbow (marked CIRC on the housing).
Drain
Line
To Gun
From
Filter
DRAIN
(stamped on hous-
ing)
CIRC
(stamped on hous-
ing)
Line
To Gun
Elbow
Director Valve
(shown in
operating mode)
Bushing
Fluid Filter
Hose To Gun
Two Gun Hookup
Draining Mode
Operating Mode
Fluid Inlet
(from pump)
0986
0987
Director Valve 214–711
5000 psi (350 bar) Maximum Working Pressure
1/4 npt(m) x 1/4 npt(m) x 1/4 npt(m)
Elbow 100–840
To direct flow from drain valve in a safe direction.
1/4 npt(f) x 1/4 npt(m)
Reducer Bushings
To connect director valve 214–711 to the outlets of the
fluid filter.
100–176
3/8 npt(m) x 1/4 npt(f)
100–206
1/2 npt(m) x 1/4 npt(f)
Manual
Change Summary
Models 224–619, 237–007, and 231–164 are obsolete
and have been deleted from the manual. Additionally a
new cart replacement and pump safety relief valve
have been incorporated.