Graco 220-730 Instructions-Parts List Manual Download Page 12

Available Tips

NOTE: Shaded part numbers are the most commonly
used contractor tip sizes.

The SwitchTip part number is marked on the handle.
For example, consider part no. 221–327. Important tip
information is contained in the last three digits. A size
327 tip has a 6–8 in. fan pattern width and a 0.027 in.
equivalent diameter orifice. To determine this informa-
tion:

Double the first digit (3) and add 2 to give the approxi-
mate fan pattern width:

3 x 2 = 6

6 + 2 = 8

6–8 in. fan pattern

Convert the next two digits (27) to a measurement in
thousandths of an inch by adding 0.0:

                         0.027 in. orifice

Remembering how to translate the tip size enables you
to quickly select the right tip for your job.

ORIFICE
SIZE

PART NUMBERS ACCORDING TO FAN WIDTH AT 12” (in inches)

(in inches)

4–6

6–8

8–10

10–12

12–14

14–16

16–18

16–18

0.005
0.009

221–405

221–609

0.011
0.013

221–211
221–213

221–311
221–313

221–411
221–413

221–511
221–513

221–611
221–613

0.015
0.017

221–215
221–217

221–315
221–317

221–415
221–417

221–515
221–517

221–615
221–617

221–817

0.019
0.021

221–219

221–319
221–321

221–419
221–421

221–519
221–521

221–619
221–621

221–721

221–819
221–821

0.023
0.025

221–325

221–423
221–425

221–523
221–525

221–623
221–625

221–723
221–725

0.027
0.029

221–327

221–427
221–429

221–527
221–529

221–627
221–629

221–729

221–827

0.031
0.033

221–431

221–531

221–631

221–831
221–833

0.035
0.039

221–435
221–439

221–535

221–635

221–735

221–835

221–935

0.043
0.045

221–443

221–543

0.051
0.055

221–451
221–455

221–551
221–555

221–655

0.063
0.065

221–563

221–665

Summary of Contents for 220-730

Page 1: ...FERENCE BLACK MAX Airless Spray Gun 3600 psi 24 8 MPa 248 bar Maximum Working Pressure Model 220 730 Series D Includes gun Reverse A Clean IV DripLess Tip Guard part no 220 422 a SwitchTip spray tip p...

Page 2: ...ot exceed the maximum working pressure of the lowest rated system component This product has a 3600 psi 24 8 MPa 248 bar Maximum Working Pressure D Use fluids and solvents which are compatible with th...

Page 3: ...gun when spraying Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 9 if the spray tip clogs and b...

Page 4: ...n the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any light switch in the spray area while operating or if fumes are pr...

Page 5: ...ressor or hydraulic power supply accord ing to local code and manufacturer s recommenda tions Fluid hoses use only grounded hoses with a maxi mum of 500 ft 150 m combined hose length to ensure groundi...

Page 6: ...hose from your pump or sprayer to the gun s 1 4 18 npt m inlet 3 Remove the RAC IV DripLess tip guard from the gun Model 220 730 only 4 Flush and then prime the pump or sprayer as instructed in the se...

Page 7: ...ou Use the appropriate gasket for the solvent used See page 8 Fully insert the SwitchTip into the guard Fully tighten the guard onto the gun nozzle using a wrench Turn the SwitchTip handle so it is pa...

Page 8: ...with the same solvents as the black rubber gasket and with lacquer thinner tricholorethylene MEK acetone brush cleaner xylol and any unknown solvents To install the RAC IV and SwitchTip WARNING Alway...

Page 9: ...l or clean the spray tips 1 Shut off the power to the pump or sprayer For an air powered pump also close the bleed type master air valve For an electric sprayer also unplug it 2 Hold a metal part of t...

Page 10: ...s in the FULL SPRAY position before operating the gun WARNING Keep clear of the nozzle High pressure fluid from leaks or spray can penetrate the sking and cause ex tremely serious injury including the...

Page 11: ...Reverse A Clean and SwitchTip Change the seat and gasket whenever a SwitchTip wears out These parts wear at about the same rate Packages of five seats and gaskets are available from your Graco distrib...

Page 12: ...tip for your job ORIFICE SIZE PART NUMBERS ACCORDING TO FAN WIDTH AT 12 in inches in inches 4 6 6 8 8 10 10 12 12 14 14 16 16 18 16 18 0 005 0 009 221 405 221 609 0 011 0 013 221 211 221 213 221 311 2...

Page 13: ...Notes...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...h above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or conse...

Reviews: