23
307679
Technical Data
Category
Data
Maximum fluid working pressure
240 psi (1.7 MPa, 16.8 bar)
Air input pressure operating range
30–120 psi (0.2–0.8 MPa, 2–8.4 bar)
Pump cycles per 1 gallon (3.8 liters)
50
Maximum recommended pump speed for
continuous operation
100 cycles/min
Air consumption
approx. 3 scfm (0.09 m
3
/min.) at 1 gpm (3.8 liters/min.) at 100 psi
(0.7 MPa, 7 bar) air pressure
Maximum operating temperature of fluid
pump
150
_
F (65.6
_
C)
Maximum operating temperature of air motor 150
_
F (65.6
_
C)
Air inlet size
1/4 npt(f)
Fluid outlet size
1/2 npt(f)
Weight
23 lb (10.4 kg)
Wetted parts
Models 218556 and 223777:
302, 303, 304, 316, and 17–4 PH
grades of stainless steel, Ultra–High Molecular Weight Polyethyl-
ene, Viton
r
,
PTFE, Polyacetal, Polyester Elastomer
r
Viton
r
r
is a
registered trademark of the Du Pont Company.
Dimensions
MODELS 218556
MODELS 223777
1/4 NPT(F)
AIR INLET
1/2 NPT(F)
FLUID OUTLET
51.93 in.
(1319 mm)
33.5 in.
(851 mm)
36.9 in.
(937 mm)
23.7 in.
(602 mm)
19.58 in.
(497 mm)
38.73 in.
(984 mm)
1/4 NPT(F)
AIR INLET
1/2 NPT(F)
FLUID OUTLET
TI1920A
TI1920A