background image

4

307476

Service

Drain the water and oil daily or when level first appears

in the sight tube (E) by opening the drain cock (F)

(clockwise to open) with the air turned OFF.

Check the filter element (G) regularly. Schedule clean-

ing by the amount of use and the condition of the air

supply and the air supply lines. Replace the filter

element if it is contaminated, or if a pressure drop is

noticed.

Fig. 2

7643A

C

G

E

F

Accessory Automatic Drain

WARNING

Make sure the air pressure to the filter-regulator is

off prior to the installation of the automatic drain.

An Accessory Automatic Drain (Part No. 106151) is

available for this assembly.

As water is accumulated in the bottom of the filter

bowl, the float assembly (H) is lifted off its seat, allow-

ing the water to drain from the filter automatically. See

Fig. 3.

Install the automatic drain by unscrewing the lower

filter housing from the upper filter housing, and drain

cock from the lower filter housing.

Fig. 3

7644A

H