1. Turn OFF power switch.

2. Connect one end of grounded fluid hose to 

spray gun. Use a wrench to tighten.

3. Connect other end of hose to sprayer fluid out-

let fitting. Use wrench to tighten.

4. Turn pressure control knob left (minimum pres-

sure).

ti2018a

ti2024a

ti15965a

ti2020a

Summary of Contents for 16J750

Page 1: ...25 ft hose Magnum X7 16J751 Series A Maximum Working Pressure 207 bar 21 MPa 3000 PSI Includes 1 17 lpm 0 31 gpm cart mount sprayer SG3 gun Manual 312830 0 635 cm 1 4 in x 15 m 50 ft hose Important Sa...

Page 2: ...Install Tip and Guard on Gun 13 Spraying Techniques 13 Getting Started 13 Unclogging Spray Tip 14 Triggering Gun 14 Aiming Gun 14 Selecting the Right Tip 15 Tip Hole Size 15 Tip Number 16 Cleanup 17 C...

Page 3: ...ug is able to result in a risk of electric shock Check with a qualified electrician or serviceman when the grounding instructions are not completely understood or when in doubt as to whether the produ...

Page 4: ...hey are antistatic or conductive Connect to a grounded outlet and use grounded extensions cords Do not use a 3 to 2 adapter Do not use a paint or a solvent containing halogenated hydrocarbons Keep spr...

Page 5: ...e lowest rated system component See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read flu...

Page 6: ...an cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read MSDSs to know the specific hazards of the fluids you are using Store hazardous fluid in approved container...

Page 7: ...trical cord has dam aged ground prong 3 Do not use an extension cord with damaged ground plug Recommended extension cords 15 m 49 2 ft 1 0 mm2 30 m 98 4 ft 1 5 mm2 50 m 164 0 ft 2 5 mm2 4 Smaller gaug...

Page 8: ...ower switch C Pressure control knob D Pump fluid outlet fitting G Suction Tube H Prime tube with diffuser J Prime Spray valve control K Fluid inlet connection and inlet valve L Inlet screen M Paint ho...

Page 9: ...ssure control knob D Pump fluid outlet fitting G Suction Tube H Prime tube with diffuser J Prime Spray valve control K Fluid inlet connection and inlet valve L Inlet screen M Paint hose P SG3 airless...

Page 10: ...e in waste pail 3 Turn Prime Spray valve to PRIME 4 Turn pressure control knob left minimum pres sure 5 Trigger gun into bucket to relieve pressure in hose Pressure Adjustment 1 Align arrow on sprayer...

Page 11: ...2 Connect one end of grounded fluid hose to spray gun Use a wrench to tighten 3 Connect other end of hose to sprayer fluid out let fitting Use wrench to tighten 4 Turn pressure control knob left mini...

Page 12: ...waste pail 5 Push pump priming button two times 6 Turn ON power switch Align arrow on sprayer and bucket symbol on pressure control knob 7 When paint without bubbles starts to come out of prime tube t...

Page 13: ...to stop pumping when gun trigger is released Getting Started Hold gun 30 cm 12 in from surface and aim straight at surface Tilting gun to direct spray angle causes an uneven finish Flex wrist to keep...

Page 14: ...ion Point the arrow shaped handle on the spray tip for ward to SPRAY and backward to UNCLOG obstructions Triggering Gun Pull trigger after starting stroke release trigger before end of stroke Gun must...

Page 15: ...ole size smaller than the maximum will allow you to spray within rated flow capacity To prevent excessive wear spray at lowest pressure that atom izes paint NOTE If maximum pressure of sprayer is not...

Page 16: ...8 10 in fan width and a 0 33 mm 0 013 in hole size order part no 286413 See manual 312830 for gun operating instructions and spray techniques Tip Part Number Fan Width 305 mm 12 in from surface Hole S...

Page 17: ...l knob 5 While pump continues to stroke remove trigger lock Trigger gun into paint pail Turn Prime Spray valve to SPRAY Continue to trig ger gun until flushing fluid comes out of gun Release trigger N...

Page 18: ...e Relief Procedure page 10 1 Engage gun trigger lock 2 Unscrew hose 3 Remove filter and clean it in compatible sol vent NOTE Do not soak entire gun in solvent Pro longed exposure to solvent can ruin p...

Page 19: ...minimum pressure 4 Turn ON power switch 5 Align arrow on sprayer with roller symbol on pressure control knob 6 When storage fluid comes out of prime tube 5 10 seconds turn OFF power switch 7 Turn Pri...

Page 20: ...nction If pump does not prime after 30 seconds try to loosen check balls by pushing pump priming button or by tapping the inlet valve with a small wrench as the sprayer is strok ing NOTE Excessive sho...

Page 21: ...drain tube as necessary Return sprayer to Graco MAGNUM authorized service center if drain valve is clogged Power switch is on and sprayer is plugged in but pump does not cycle Pressure set at minimum...

Page 22: ...raying Pump cycles but paint only dribbles or spurts when trigger is pulled Pressure is set too low Turn pressure control knob right to increase pressure Spray tip clogged Clean tip See Gun stops spra...

Page 23: ...ressure setting or increase tip size Move sprayer to cooler location Building circuit breaker opens after sprayer operates for 5 10 minutes OR Building circuit breaker opens as soon as sprayer is plug...