Remote Loading

3A1244F

3

9.

Upgrade all other modules in the system to the soft-
ware revision on the token, if not already completed. 
Different software versions may not be compatible.

NOTE: 

If the software on the token is the same version 

that is already programmed on the module, nothing will 
happen (including flashing red light). No harm can be 
done by attempting to program the module multiple 
times. For Communications Gateway Modules, installing 
upgrade software will not erase or overwrite a data map, 
if already loaded.

Remote Loading

Systems With Advanced Display Module 
(ADM), 24E451

1.

The following screen will be shown when the display 
turns on.

2.

Select which software is applied to each module 
when multiple software options exist. The following 
screen is not present in all systems. See system 

specific manual for more details. Press 

 to 

continue.

3.

Wait for update to complete.

NOTE: 

The approximate time until completion is shown 

along bottom of progress bar.

4.

Updates are complete. Icon indicates update 

success or failure. See Icon Table. Press 

 to 

continue.

Display on System

Page

Advanced Module (ADM), 24E451

3

Display Module 262384, 24F493

4

Display Control Module, 24L096, or Advanced 
Display Control Module, 24L097

5

Communications with other modules established.

Key:

A

Module Serial Number

B

Software currently on module

C

Software available for module

A

B

C

Icon

Description

Update successful

Update unsuccessful

Update complete; no change necessary.

Modules were updated or didn’t require an 
update; however, one or more modules 
need to be updated manually with a token.

Summary of Contents for 15V759

Page 1: ...ssional use only See your system manual when replacing parts in hazardous locations NOTE An upgrade token is needed to program modules See system manual for token part num ber Important Safety Instructions Read all warnings and instructions in this manual and your system manuals Save these instructions ti16440a Display Module USB Module Advanced Fluid Control Module Not all modules shown ...

Page 2: ...over is removed by pressing in the two tabs For other modules one or more screws S must be removed 3 Insert and press the token T firmly into the slot NOTE Token has no preferred orientation 4 Supply electrical power to the Graco Control Archi tecture Module using either system power or Power Supply Kit 24F672 available separately NOTE The Motor Control Module 257696 High Power Temperature Control...

Page 3: ...o each module when multiple software options exist The following screen is not present in all systems See system specific manual for more details Press to continue 3 Wait for update to complete NOTE The approximate time until completion is shown along bottom of progress bar 4 Updates are complete Icon indicates update success or failure See Icon Table Press to continue Display on System Page Advan...

Page 4: ...pdate to complete NOTE The approximate time until completion is shown along bottom of progress bar 4 Updates are complete Icon indicates update success or failure See Icon Table Press to continue Communications with other modules established Key A Module Serial Number B Software currently on module C Software available for module A B C Icon Description Update successful Update unsuccessful Update ...

Page 5: ... 3 Wait for update to complete NOTE The approximate time until completion is shown along bottom of progress bar 4 Updates are complete Icon indicates update success or failure See Icon Table Press to continue Communications with other modules established Key A Module Serial Number B Software currently on module C Software available for module A B C Icon Description Update successful Update unsucce...

Page 6: ...dules 6 3A1244F Available Graco Control Architecture Modules Display Module 262384 24F493 Advanced Fluid Control Module 255920 USB Module 289900 Advanced Display Module 24E451 S C T red light S C T L ti16439a T L ti17215a C ti17216a T L S C ...

Page 7: ... 3A1244F 7 Communications Gateway Module 15V759 15V760 15V761 15V762 289835 289836 289837 289838 Discrete Gateway Module 24B681 Fluid Control Module 289696 Local Control Module 262416 ti17217a T L C ti17218a T L C ti17219a T L C ti17220a T L C S ...

Page 8: ... High Power Temperature Control Module 255774 Low Power Temperature Control Module 256270 Motor Control Module 257396 Display Control Module 24L096 and Advanced Display Control Module 24L097 ti17221a T L C ti17222a T L C ti17223a T L S S C ti19597a T C S L ...

Page 9: ...in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of war...

Reviews: