background image

Installation 

8

313212B

Connect the Cable to the 
RoboMix Control Board

1.

See the ProMix 2KS Repair-Parts manual. Open the 
RoboMix to access the control board.

2.

Connect the 10 position connector (24) to J1 on the 
control board. See F

IG

. 9.

3.

Connect the 6 position connector (25) to J8 on the 
control board. See F

IG

. 10

NOTICE

To avoid damaging circuit board when servicing, wear 
grounding strap on wrist and ground appropriately.

F

IG

. 9: RoboMix Control Board J1 Connections

F

IG

. 10: RoboMix Control Board J8 Connections

J1 Pins 1-4, 7-10

(10 position

Connector 24)

J8 Pins 1-4
(6 position Connector 25)

Summary of Contents for 15V534

Page 1: ...d in conjunction with ProMix 2KS Electronic Proportioners 100 psi 0 7 MPa 7 bar Maximum Air Input Pressure Important Safety Instructions Read all warnings and instructions in this manual For complete...

Page 2: ...nnections to enable a ProMix 2KS RoboMix proportioner to operate one or two gun flush boxes See FIG 1 for the identification label Order Gun Flush Box Kit 15V826 separately see man ual 312784 Each 15V...

Page 3: ...ent height for the operator and so equipment is easily accessi ble for maintenance 4 Drill mounting holes in the wall Install anchors as needed 5 Bolt equipment securely To avoid electric shock ground...

Page 4: ...of the 10 position connector 24 and pins 1 4 of the 6 position connector as shown in the Cable 23 Wire Harness Detail on page 11 FIG 2 Connect Cable to Terminal Strip 20 12 TI14279a 7 Table 1 Terminal...

Page 5: ...he switch es in the right side of the enclosure See FIG 3 2 Connect the wires from AFS 1 to the right side of the terminal strip 12 pins 1 2 as indicated by the label 21 See FIG 4 and Table 1 3 If usi...

Page 6: ...stall the switch es in the left side of the enclosure See FIG 5 2 Connect the wires from PS 1 to the right side of the terminal strip 12 pins 5 6 as indicated by the label 21 See FIG 6 and Table 1 3 I...

Page 7: ...remove the two sealing screws 4 from the solenoid manifold 8 before installing SO 2 Also remove the plug 5 from the connector 15 2 Connect the wires from SO 1 to the right side of the terminal strip...

Page 8: ...24 to J1 on the control board See FIG 9 3 Connect the 6 position connector 25 to J8 on the control board See FIG 10 NOTICE To avoid damaging circuit board when servicing wear grounding strap on wrist...

Page 9: ...zing air safety shutoff valve IN port See the gun flush box manual for details on the safety shutoff valve Connect Air Supply to Module Connect a 1 4 in 6 mm OD tube between a clean dry air supply fil...

Page 10: ...Installation 10 313212B...

Page 11: ...art No Description Qty 1 15V531 ENCLOSURE GFB module 1 3 118435 GROMMET 1 4 121628 SCREW self sealing 4 5 113279 PLUG fitting tube 1 6 116343 SCREW ground 1 7 114421 BUSHING strain relief 1 8 15V533 M...

Page 12: ...ent location near the RoboMix Bring the cable to the RoboMix and thread it through the cable path at the back 2 See the ProMix 2KS Repair Parts manual Open the RoboMix to access the control board 3 Co...

Page 13: ...6 75 in 171 5 mm 7 50 in 190 5 mm 6 28 in 159 5 mm 4 00 in 101 6 mm 4 00 in 101 6 mm Mounting Holes Maximum Air Input Pressure 100 psi 0 7 MPa 7 bar Air Inlet Size 1 4 in 6 mm OD tube connector Air O...

Page 14: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Reviews: