313212B

ENG

Instructions-Parts

15V534 Gun Flush 
Box Interface Kit

Interfaces a Graco Gun Flush Box with a ProMix

®

 2KS Electronic Proportioner using a 

RoboMix Fluid Station. For professional use only.

Approved for use in explosive atmospheres only when used in conjunction with ProMix 
2KS Electronic Proportioners.

100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure

Important Safety Instructions

Read all warnings and instructions in this manual. For complete 
warnings and instructions see your proportioning system manual 
and gun flush box manual 312784. Hazard symbols refer to spe-
cific procedure risks. Save all instructions.

TI14275a

GFB Interface Kit shown with 
two air flow switches installed

II 2 G

#

53

2575

Summary of Contents for 15V534

Page 1: ...d in conjunction with ProMix 2KS Electronic Proportioners 100 psi 0 7 MPa 7 bar Maximum Air Input Pressure Important Safety Instructions Read all warnings and instructions in this manual For complete...

Page 2: ...nnections to enable a ProMix 2KS RoboMix proportioner to operate one or two gun flush boxes See FIG 1 for the identification label Order Gun Flush Box Kit 15V826 separately see man ual 312784 Each 15V...

Page 3: ...ent height for the operator and so equipment is easily accessi ble for maintenance 4 Drill mounting holes in the wall Install anchors as needed 5 Bolt equipment securely To avoid electric shock ground...

Page 4: ...of the 10 position connector 24 and pins 1 4 of the 6 position connector as shown in the Cable 23 Wire Harness Detail on page 11 FIG 2 Connect Cable to Terminal Strip 20 12 TI14279a 7 Table 1 Terminal...

Page 5: ...he switch es in the right side of the enclosure See FIG 3 2 Connect the wires from AFS 1 to the right side of the terminal strip 12 pins 1 2 as indicated by the label 21 See FIG 4 and Table 1 3 If usi...

Page 6: ...stall the switch es in the left side of the enclosure See FIG 5 2 Connect the wires from PS 1 to the right side of the terminal strip 12 pins 5 6 as indicated by the label 21 See FIG 6 and Table 1 3 I...

Page 7: ...remove the two sealing screws 4 from the solenoid manifold 8 before installing SO 2 Also remove the plug 5 from the connector 15 2 Connect the wires from SO 1 to the right side of the terminal strip...

Page 8: ...24 to J1 on the control board See FIG 9 3 Connect the 6 position connector 25 to J8 on the control board See FIG 10 NOTICE To avoid damaging circuit board when servicing wear grounding strap on wrist...

Page 9: ...zing air safety shutoff valve IN port See the gun flush box manual for details on the safety shutoff valve Connect Air Supply to Module Connect a 1 4 in 6 mm OD tube between a clean dry air supply fil...

Page 10: ...Installation 10 313212B...

Page 11: ...art No Description Qty 1 15V531 ENCLOSURE GFB module 1 3 118435 GROMMET 1 4 121628 SCREW self sealing 4 5 113279 PLUG fitting tube 1 6 116343 SCREW ground 1 7 114421 BUSHING strain relief 1 8 15V533 M...

Page 12: ...ent location near the RoboMix Bring the cable to the RoboMix and thread it through the cable path at the back 2 See the ProMix 2KS Repair Parts manual Open the RoboMix to access the control board 3 Co...

Page 13: ...6 75 in 171 5 mm 7 50 in 190 5 mm 6 28 in 159 5 mm 4 00 in 101 6 mm 4 00 in 101 6 mm Mounting Holes Maximum Air Input Pressure 100 psi 0 7 MPa 7 bar Air Inlet Size 1 4 in 6 mm OD tube connector Air O...

Page 14: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...