![Graco 150 RPX Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/graco/150-rpx/150-rpx_operating-instructions-manual_2252635005.webp)
5
309388
Grounding and Electric Requirements
D
Ground solvent pails used when flushing
. Follow local code. Use
only conductive, metal pails, placed on a grounded surface such as
concrete. Do not place the pail on a non–conductive surface such
as paper or cardboard, which interrupts the grounding continuity.
ti5850a
ti5851a
D
Ground the metal pail
by connecting a ground wire to the
pail by clamping one end to pail and the other end to
ground such as as water pipe.
D
Maintain grounding continuity
when flushing or
relieving pressure by holding metal part of spray gun
firmly to side of a grounded metal pail, then trigger gun.
Thermal Overload
D
Motor has a thermal overload switch
to shut itself down if overheated.
To reduce risk of injury from motor staring
unexpectedly when it cools, always turn power