33
309388
1.
Engage In–line Valve safety latch.
2.
Hold In–line Valve with nozzle straight up.
3.
Remove trigger guard.
Service
– Adjusting the Needle on the Contractor
t
In–line Valve
4.
Hold your finger against trigger with light pressure.
Using a 5/16–in, open ended wrench, turn locknut
clockwise until you feel trigger depress slightly.
5/16”