N1 MECHANICAL MALFUNCTIONS
WARNING
TOXIC FLUID OR FUMES HAZARD
Correct and regular maintenance of the nozzle
and of the system to which it is connected prevents
malfunctions and possible accidental and possible
accidental spills of hazardous liquids.
FOREWORD
THE POSSIBLE CAUSES OF MALFUNCTION ARE MAINLY ATTRIBUT-
ABLE TO THREE FACTORS:
1
NOZZLE DIRTY IN INNER HOLE OF LIP AT END OF SPOUT
2
OPERATING PRESSURE OF LIQUID TO BE DISPENSED BELOW 0.5 bar
OR ABOVE 3.5 bar
3
FLOW RATE TOO LOW OR TOO HIGH
N2 ELECTRONIC MALFUNCTIONS
Problem
Possible cause
Remedial Action
LCD: no indication
Bad battery contact
Check battery contacts
Not enough measurement
precision
Wrong K FACTOR
With reference to paragraph H,
check the K FACTOR
The meter works below
minimum acceptable fl w rate.
Increase the fl w rate until an ac-
ceptable fl w rate range has been
achieved
Reduced or zero fl w rate
TURBINE blocked
Clean the TURBINE
The meter does not count, but
the fl w rate is correct
Incorrect installation of
gears after cleaning
Repeat the reassembly procedure
Possible electronic card problems Contact your dealer
Summary of Contents for 127650
Page 22: ...22 M0303 EN Q DIMENSIONS 190 160 79 433 190 19 Ø 20 Ø 3 4 HOSE ...
Page 25: ...Cette page est intentionnellement laissée en blanc ...
Page 52: ...Esta página se ha dejado en blanco intencionadamente ...
Page 76: ...76 M0302 ES Q DIMENSIONES TOTALES 190 160 79 433 190 19 Ø 20 Ø 3 4 HOSE ...
Page 78: ...Esta página se ha dejado en blanco intencionadamente ...
Page 79: ...Esta página se ha dejado en blanco intencionadamente ...