6
M0309
EN
F
TECHNICAL DATA
F1
PERFORMANCE SPECIFICATIONS
The performance diagram shows fl w rate as a function of back pressure.
Functioning
Point
Flo
w R
at
e
(litr
es/minut
e)
Voltage (
V)
Amps (
A)
Typical Delivery Configu ation
No
. 4
metr
es
of
¾”
pipe
-
K24 M
et
er
M
anual no
zzle
Aut
oma
tic
Dispensing
No
zzle
A
(Maximum fl w rate)
36
12
16
•
•
B
(High fl w rate)
33
12
17
•
•
•
C
(Normal conditions)
30
12
19
•
•
•
D
(By pass)
0
12
20
Delivery closed
NOTE
The curve refers to the following operating condi-
tions:
Fluid: DEF
Temperature: 20° C (68 °F)
Suction conditions: The pipe and the pump position
relative to the fluid level is such that a low pressure
of 0.3 bar (4 psi) is generated at the nominal flow
rate.
Under different suction conditions higher low
pressure values can be created that reduce the flow
rate compared to the same back pressure values. To
obtain the best performance, it is very important to
reduce loss of suction pressure as much as possible
by following these instructions:
• shorten the suction pipe as much as possible
• avoid useless elbows or throttling in the pipes
• keep the suction filter clean
• use a pipe with a diameter equal to, or greater
than, indicated (see Installation).
NOTE
By-pass pressure is 1.7 bar (24 psi)
NOTE
The wetted materials used in this device are :
stainless steel, plastic and rubber suitable for AdBlue.