Operation
309200D
5
Operation
Visual and Remote Indicator Light Display (F
IG
. 3, page 5)
Full Level Mark
- rod is visible at this mark and indicates that the lubrication supply container is full. No additional
lubricant need to be added.
Full Level Range
- rod is visible in this range and indicates that the main lubrication supply container is nearing full
and does not need to be refilled.
Normal Level Mark
- rod is visible at this mark and indicates that the lubrication supply container has sufficient mate-
rial. No additional lubricant is needs to be added.
Low Level Range
- rod is visible in this range and indicates that the lubrication supply container is approaching the
low level mark and needs to be refilled.
Low Level Mark
- rod is visible at this mark and indicates that the main lubrication supply container is low and needs
to be refilled.
Remote Full Level Indicator Light
- when lit, indicates the main lubrication supply container is full. No additional
lubricant needs to be added.
Remote Low Level Indicator Light
- when lit, indicates the main lubrication supply container is low and needs to be
refilled.
F
IG
. 3
ti11448a
Full
level mark
Normal
level mark
Low
level mark
{
{
Full Level Range
- rod in
this range indicates reservoir
.is nearing full.
Low Level Range
- rod in
this range indicates reservoir
.is approaching the low level
mark and needs to be refilled.
Do not overfill
so that rod
extends past the full level mark.
NOTICE
Do not
allow rod to surpass
low level mark.
NOTICE
Red wires to
Remote Low
Level Indicator
Light Device
24V 1 amp. ma.
Black wires to
Remote
Full Level Indicator
Light